CONTEXT: Cross sectional imaging with computed tomography (CT) or magnetic resonance imaging (MRI) is regarded as a first-choice modality for tumor localization in patients with pheochromocytoma and paraganglioma (PPGL). 123I-labeled metaiodobenzylguanidine (123I-MIBG) is widely used for functional imaging but the added diagnostic value is controversial. OBJECTIVE: To establish the virtual impact of adding 123I-MIBG scintigraphy to CT or MRI on diagnosis and treatment of PPGL. DESIGN: International multicenter retrospective study. INTERVENTION: None. PATIENTS: 236 unilateral adrenal, 18 bilateral adrenal, 48 unifocal extra-adrenal, 12 multifocal and 26 metastatic PPGL. MAIN OUTCOME MEASURES: Patients underwent both anatomical imaging (CT and/or MRI) and 123I-MIBG scintigraphy. Local imaging reports were analyzed centrally by two independent observers who were blinded to the diagnosis. Imaging-based diagnoses determined by CT/MRI only, 123I-MIBG only, and CT/MRI combined with 123I-MIBG scintigraphy were compared with the correct diagnoses. RESULTS: The rates of correct imaging-based diagnoses determined by CT/MRI only versus CT/MRI plus 123I-MIBG scintigraphy were similar: 89.4 versus 88.8%, respectively, (P=0.50). Adding 123I-MIBG scintigraphy to CT/MRI resulted in a correct change in the imaging-based diagnosis and ensuing virtual treatment in four cases (1.2%: two metastatic instead of non-metastatic, one multifocal instead of single, one unilateral instead of bilateral adrenal) at the cost of an incorrect change in seven cases (2.1%: four metastatic instead of non-metastatic, two multifocal instead of unifocal and one bilateral instead of unilateral adrenal). CONCLUSIONS: For the initial localization of PPGL, the addition of 123I-MIBG scintigraphy to CT/MRI rarely improves the diagnostic accuracy at the cost of incorrect interpretation in others, even when 123I-MIBG scintigraphy is restricted to patients who are at risk for metastatic disease. In this setting, the impact of 123I-MIBG scintigraphy on clinical decision-making appears very limited.

Impact of 123I-MIBG Scintigraphy on Clinical Decision-Making in Pheochromocytoma and Paraganglioma / Rao D.; Van Berkel A.; Piscaer I.; Young W.F.; Gruber L.; Deutschbein T.; Fassnacht M.; Beuschlein F.; Spyroglou A.; Prejbisz A.; Hanus K.; Eisenhofer G.; Manelli M.; Canu L.; Lenders J.W.M.; Bancos I.; Timmers H.J.L.M.. - In: THE JOURNAL OF CLINICAL ENDOCRINOLOGY AND METABOLISM. - ISSN 0021-972X. - ELETTRONICO. - 104:(2019), pp. 3812-3820. [10.1210/jc.2018-02355]

Impact of 123I-MIBG Scintigraphy on Clinical Decision-Making in Pheochromocytoma and Paraganglioma

Rao D.;Canu L.;
2019

Abstract

CONTEXT: Cross sectional imaging with computed tomography (CT) or magnetic resonance imaging (MRI) is regarded as a first-choice modality for tumor localization in patients with pheochromocytoma and paraganglioma (PPGL). 123I-labeled metaiodobenzylguanidine (123I-MIBG) is widely used for functional imaging but the added diagnostic value is controversial. OBJECTIVE: To establish the virtual impact of adding 123I-MIBG scintigraphy to CT or MRI on diagnosis and treatment of PPGL. DESIGN: International multicenter retrospective study. INTERVENTION: None. PATIENTS: 236 unilateral adrenal, 18 bilateral adrenal, 48 unifocal extra-adrenal, 12 multifocal and 26 metastatic PPGL. MAIN OUTCOME MEASURES: Patients underwent both anatomical imaging (CT and/or MRI) and 123I-MIBG scintigraphy. Local imaging reports were analyzed centrally by two independent observers who were blinded to the diagnosis. Imaging-based diagnoses determined by CT/MRI only, 123I-MIBG only, and CT/MRI combined with 123I-MIBG scintigraphy were compared with the correct diagnoses. RESULTS: The rates of correct imaging-based diagnoses determined by CT/MRI only versus CT/MRI plus 123I-MIBG scintigraphy were similar: 89.4 versus 88.8%, respectively, (P=0.50). Adding 123I-MIBG scintigraphy to CT/MRI resulted in a correct change in the imaging-based diagnosis and ensuing virtual treatment in four cases (1.2%: two metastatic instead of non-metastatic, one multifocal instead of single, one unilateral instead of bilateral adrenal) at the cost of an incorrect change in seven cases (2.1%: four metastatic instead of non-metastatic, two multifocal instead of unifocal and one bilateral instead of unilateral adrenal). CONCLUSIONS: For the initial localization of PPGL, the addition of 123I-MIBG scintigraphy to CT/MRI rarely improves the diagnostic accuracy at the cost of incorrect interpretation in others, even when 123I-MIBG scintigraphy is restricted to patients who are at risk for metastatic disease. In this setting, the impact of 123I-MIBG scintigraphy on clinical decision-making appears very limited.
2019
104
3812
3820
Rao D.; Van Berkel A.; Piscaer I.; Young W.F.; Gruber L.; Deutschbein T.; Fassnacht M.; Beuschlein F.; Spyroglou A.; Prejbisz A.; Hanus K.; Eisenhofer G.; Manelli M.; Canu L.; Lenders J.W.M.; Bancos I.; Timmers H.J.L.M.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1180384
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 11
social impact