Poor inhaler technique hampers the efficacy of drug therapy in asthma and chronic obstructive pulmonary disease. Not only does this affect individual patient care, but it also impacts on the wider health care economics associated with these conditions. Treatment guidelines recommend a systematic approach to drug class selection; however, standardization of inhaler selection is currently difficult owing to the complexity of the interaction between the inhaler device and the patient. Specifically, individual patient preference can influence how successful a treatment is overall. This article reviews inhaler devices from the patient perspective, with a particular focus on the dry powder inhaler HandiHaler(®) and Respimat(®) Soft Mist™ Inhaler. It discusses factors that influence device preference and treatment compliance and reviews tools that can aid health care professionals to better match inhaler devices to individual patients' needs.
Patients’ perspectives and preferences in the choice of inhalers: The case for Respimat® or HandiHaler® / Dekhuijzen P.N.R.; Lavorini F.; Usmani O.S.. - In: PATIENT PREFERENCE AND ADHERENCE. - ISSN 1177-889X. - ELETTRONICO. - 10:(2016), pp. 1561-1572. [10.2147/PPA.S82857]
Patients’ perspectives and preferences in the choice of inhalers: The case for Respimat® or HandiHaler®
Lavorini F.Membro del Collaboration Group
;
2016
Abstract
Poor inhaler technique hampers the efficacy of drug therapy in asthma and chronic obstructive pulmonary disease. Not only does this affect individual patient care, but it also impacts on the wider health care economics associated with these conditions. Treatment guidelines recommend a systematic approach to drug class selection; however, standardization of inhaler selection is currently difficult owing to the complexity of the interaction between the inhaler device and the patient. Specifically, individual patient preference can influence how successful a treatment is overall. This article reviews inhaler devices from the patient perspective, with a particular focus on the dry powder inhaler HandiHaler(®) and Respimat(®) Soft Mist™ Inhaler. It discusses factors that influence device preference and treatment compliance and reviews tools that can aid health care professionals to better match inhaler devices to individual patients' needs.File | Dimensione | Formato | |
---|---|---|---|
ppa-10-1561.pdf
accesso aperto
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
900.79 kB
Formato
Adobe PDF
|
900.79 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.