ECG recordings from consecutive patients with HCM simulating the S-ICD sensing vectors were analyzed with the S-ICD screening tool. Eligibility was defined by 1 or 2 appropriate vectors. Medical history, ultrasound characteristics, and 12-lead ECG characteristics were analyzed and the individual arrhythmic risk at 5 year was determined to study potential predictors of failure. One hundred sixty-five (118 men; mean age 51 ± 16 years) patients were analyzed. Twenty-two patients (13%) had a high risk of sudden cardiac death, 33 (20%) had intermediate to high risk, and 110 (67%) had low risk. Twenty-six patients (16%) had no suitable vector, including 8 of 22 high-risk patients (36%). The primary cause of failure was high T-wave voltages in 25% of the vectors analyzed. T-wave inversions in >2 leads on the surface 12-lead ECG (odds ratio 15.6; 95% confidence interval 4.9–50.3; P < .001) and prior myectomy (odds ratio 8.4; 95% confidence interval 2.1–33.1; P = .002) were significantly associated with screening failure in a multivariable model. Currently available preimplant screening algorithms recommended by the manufacturer are associated with a significant failure rate in patients with HCM, particularly in the high-risk subgroup.

Prevalence of subcutaneous implantable cardioverter-defibrillator candidacy based on template ECG screening in patients with hypertrophic cardiomyopathy / Maurizi N.; Olivotto I.; Olde Nordkamp L.R.A.; Baldini K.; Fumagalli C.; Brouwer T.F.; Knops R.E.; Cecchi F.. - In: HEART RHYTHM. - ISSN 1547-5271. - STAMPA. - 13:(2016), pp. 457-463. [10.1016/j.hrthm.2015.09.007]

Prevalence of subcutaneous implantable cardioverter-defibrillator candidacy based on template ECG screening in patients with hypertrophic cardiomyopathy

Maurizi N.;Olivotto I.;Fumagalli C.;Cecchi F.
2016

Abstract

ECG recordings from consecutive patients with HCM simulating the S-ICD sensing vectors were analyzed with the S-ICD screening tool. Eligibility was defined by 1 or 2 appropriate vectors. Medical history, ultrasound characteristics, and 12-lead ECG characteristics were analyzed and the individual arrhythmic risk at 5 year was determined to study potential predictors of failure. One hundred sixty-five (118 men; mean age 51 ± 16 years) patients were analyzed. Twenty-two patients (13%) had a high risk of sudden cardiac death, 33 (20%) had intermediate to high risk, and 110 (67%) had low risk. Twenty-six patients (16%) had no suitable vector, including 8 of 22 high-risk patients (36%). The primary cause of failure was high T-wave voltages in 25% of the vectors analyzed. T-wave inversions in >2 leads on the surface 12-lead ECG (odds ratio 15.6; 95% confidence interval 4.9–50.3; P < .001) and prior myectomy (odds ratio 8.4; 95% confidence interval 2.1–33.1; P = .002) were significantly associated with screening failure in a multivariable model. Currently available preimplant screening algorithms recommended by the manufacturer are associated with a significant failure rate in patients with HCM, particularly in the high-risk subgroup.
2016
13
457
463
Maurizi N.; Olivotto I.; Olde Nordkamp L.R.A.; Baldini K.; Fumagalli C.; Brouwer T.F.; Knops R.E.; Cecchi F.
File in questo prodotto:
File Dimensione Formato  
Lavoro_S_ICD_HCM_SCREENING_NICCOLO'.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 464.49 kB
Formato Adobe PDF
464.49 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1181125
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 42
social impact