OBJECTIVES: Contrast-enhanced ultrasonography (CEUS) allows the study of vascularization of secondary liver lesions. The Cyberknife (Accuray, Inc, Sunnyvale, CA) is a therapeutic method that allows a tumor target to be subjected to a high radiant dose gradient. This prospective pilot study aimed to demonstrate the concordance of CEUS versus contrast-enhanced computed tomography (CECT) in determining the stability or disease progression of secondary liver lesions after treatment with the Cyberknife. METHODS: Twenty-four patients were consecutively enrolled, and 3 different operators evaluated the CEUS images and the intermodality concordance with CECT. All patients received CEUS at 1 and 2 months after the Cyberknife therapy. The intermodality agreement was evaluated by the Cohen κ coefficient and a multivariate analysis according to the method of Janson and Olsson (Educ Psychol Meas 2001; 61:277-289). RESULTS: Forty secondary liver lesions were detected and treated. Forty-one CECT and 51 CEUS examinations were performed without any adverse events in the 24 patients. The intermodality agreement rates, calculated for the operators as Cohen κ values, were κ = 1.00, 0.881, and 0.767, respectively. The multivariate analysis of intermodality agreement showed an almost perfect value (ι = 0.841). CONCLUSIONS: This pilot study found excellent diagnostic correspondence between CEUS and CECT in the evaluation of local disease stability or progression after Cyberknife therapy in liver metastases. These findings suggest that CEUS could play an important role in the surveillance of these patients because of its high accuracy and reproducibility, thus reducing the need for CECT. © 2018 by the American Institute of Ultrasound in Medicine.
Computed tomography or contrast-enhanced ultrasonography for follow-up of liver metastases after Cyberknife therapy?: A prospective pilot study / Marsico, Maria; Gabbani, Tommaso; Lunardi, Sarah; Lei, Barbara; Lucarini, Matteo; Cuffari, Biagio; Curatolo, Angela; Biagini, Maria Rosa; Annese, Vito. - In: JOURNAL OF ULTRASOUND IN MEDICINE. - ISSN 1550-9613. - STAMPA. - 38:(2019), pp. 649-655. [10.1002/jum.14734]
Computed tomography or contrast-enhanced ultrasonography for follow-up of liver metastases after Cyberknife therapy?: A prospective pilot study
Biagini, Maria Rosa;
2019
Abstract
OBJECTIVES: Contrast-enhanced ultrasonography (CEUS) allows the study of vascularization of secondary liver lesions. The Cyberknife (Accuray, Inc, Sunnyvale, CA) is a therapeutic method that allows a tumor target to be subjected to a high radiant dose gradient. This prospective pilot study aimed to demonstrate the concordance of CEUS versus contrast-enhanced computed tomography (CECT) in determining the stability or disease progression of secondary liver lesions after treatment with the Cyberknife. METHODS: Twenty-four patients were consecutively enrolled, and 3 different operators evaluated the CEUS images and the intermodality concordance with CECT. All patients received CEUS at 1 and 2 months after the Cyberknife therapy. The intermodality agreement was evaluated by the Cohen κ coefficient and a multivariate analysis according to the method of Janson and Olsson (Educ Psychol Meas 2001; 61:277-289). RESULTS: Forty secondary liver lesions were detected and treated. Forty-one CECT and 51 CEUS examinations were performed without any adverse events in the 24 patients. The intermodality agreement rates, calculated for the operators as Cohen κ values, were κ = 1.00, 0.881, and 0.767, respectively. The multivariate analysis of intermodality agreement showed an almost perfect value (ι = 0.841). CONCLUSIONS: This pilot study found excellent diagnostic correspondence between CEUS and CECT in the evaluation of local disease stability or progression after Cyberknife therapy in liver metastases. These findings suggest that CEUS could play an important role in the surveillance of these patients because of its high accuracy and reproducibility, thus reducing the need for CECT. © 2018 by the American Institute of Ultrasound in Medicine.File | Dimensione | Formato | |
---|---|---|---|
jum.14734.pdf
accesso aperto
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Open Access
Dimensione
842.5 kB
Formato
Adobe PDF
|
842.5 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.