Surgical sta behavior in operating theatres is one of the factors associated with indoor air quality and surgical site infection risk. The aim of this study was to apply an approach including microbiological, particle, and microclimate parameters during two simulated surgical hip arthroplasties to evaluate the influence of sta behavior on indoor air quality. During the first hip arthroplasty, the surgical team behaved correctly, but in the second operation, behavioral recommendations were not respected. Microbiological contamination was evaluated by active and passive methods. The air velocity, humidity, temperature, and CO2 concentration were also monitored. The highest levels of microbial and particle contamination, as well as the highest variation in the microclimate parameter, were recorded during the surgical operation where the surgical team behaved “incorrectly”. Turbulent air flow ventilation systems appeared more ecient than in the past and very low air microbial contamination was reached when behavior was correct. Therefore, adherence to behavioral recommendations in operating theatres is essential to not undermine the eectiveness of the heating, ventilation, and air conditioning systems and employed resources.

The Influence of Surgical Staff Behavior on Air Quality in a Conventionally Ventilated Operating Theatre during a simulated Arthroplasty: A Case Study at the University Hospital of Parma / Pasquarella C.; Balocco C.; Colucci M.E.; Saccani E.; Paroni S.; Albertini L.; Vitali P; Albertini R.. - In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH. - ISSN 1660-4601. - STAMPA. - 17(452):(2020), pp. 1-14. [10.3390/ijerph17020452]

The Influence of Surgical Staff Behavior on Air Quality in a Conventionally Ventilated Operating Theatre during a simulated Arthroplasty: A Case Study at the University Hospital of Parma

Balocco C.
;
2020

Abstract

Surgical sta behavior in operating theatres is one of the factors associated with indoor air quality and surgical site infection risk. The aim of this study was to apply an approach including microbiological, particle, and microclimate parameters during two simulated surgical hip arthroplasties to evaluate the influence of sta behavior on indoor air quality. During the first hip arthroplasty, the surgical team behaved correctly, but in the second operation, behavioral recommendations were not respected. Microbiological contamination was evaluated by active and passive methods. The air velocity, humidity, temperature, and CO2 concentration were also monitored. The highest levels of microbial and particle contamination, as well as the highest variation in the microclimate parameter, were recorded during the surgical operation where the surgical team behaved “incorrectly”. Turbulent air flow ventilation systems appeared more ecient than in the past and very low air microbial contamination was reached when behavior was correct. Therefore, adherence to behavioral recommendations in operating theatres is essential to not undermine the eectiveness of the heating, ventilation, and air conditioning systems and employed resources.
2020
17(452)
1
14
Pasquarella C.; Balocco C.; Colucci M.E.; Saccani E.; Paroni S.; Albertini L.; Vitali P; Albertini R.
File in questo prodotto:
File Dimensione Formato  
ijerph-17-00452_Balocco&Alii2020.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.41 MB
Formato Adobe PDF
1.41 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1181681
Citazioni
  • ???jsp.display-item.citation.pmc??? ND