This paper focuses on the validation of smart textile electrodes used to acquire ECG signals in horses in a comfortable and robust manner. The performance of smart textile electrodes is compared with standard Ag/AgCl electrodes in terms of the percentage of Motion Artifacts (MAs, the noise that results from the movement of electrodes against the skin) and signal quality. Seven healthy Standardbred mares were equipped with two identical electronic systems for the simultaneous collection of ECGs. One system was equipped with smart textile electrodes, while the second was equipped with standard Ag/AgCl electrodes. Each horse was then monitored individually in a stall for one hour, without any movement constraints. The ECGs were visually examined by an expert who blindly labeled the ECG segments that had been corrupted by MAs. Finally, the percentage of MAs (MA%) was computed as the number of samples of the corrupted segments over the whole length of the signal. The total MA% was found to be lower for the smart textiles than for the Ag/AgCl electrodes. Consistent results were also obtained by investigating MAs over time. These results suggest that smart textile electrodes are more reliable when recording artefact-free ECGs in horses at rest. Thus, improving the acquisition of important physiological information related to the activity of the Autonomic Nervous System, such as Heart Rate Variability, could help to provide reliable information on the mood and state of arousal of horses.

Validation of smart-textile electrodes for electrocardiogram monitoring in free-moving horses / GUIDI, ANDREA; LANATA', ANTONIO; VALENZA, GAETANO; SCILINGO, ENZO PASQUALE; BARAGLI, PAOLO. - In: JOURNAL OF VETERINARY BEHAVIOR. - ISSN 1558-7878. - ELETTRONICO. - 1:(2017), pp. 19-23. [10.1016/j.jveb.2016.10.001]

Validation of smart-textile electrodes for electrocardiogram monitoring in free-moving horses

LANATA', ANTONIO;
2017

Abstract

This paper focuses on the validation of smart textile electrodes used to acquire ECG signals in horses in a comfortable and robust manner. The performance of smart textile electrodes is compared with standard Ag/AgCl electrodes in terms of the percentage of Motion Artifacts (MAs, the noise that results from the movement of electrodes against the skin) and signal quality. Seven healthy Standardbred mares were equipped with two identical electronic systems for the simultaneous collection of ECGs. One system was equipped with smart textile electrodes, while the second was equipped with standard Ag/AgCl electrodes. Each horse was then monitored individually in a stall for one hour, without any movement constraints. The ECGs were visually examined by an expert who blindly labeled the ECG segments that had been corrupted by MAs. Finally, the percentage of MAs (MA%) was computed as the number of samples of the corrupted segments over the whole length of the signal. The total MA% was found to be lower for the smart textiles than for the Ag/AgCl electrodes. Consistent results were also obtained by investigating MAs over time. These results suggest that smart textile electrodes are more reliable when recording artefact-free ECGs in horses at rest. Thus, improving the acquisition of important physiological information related to the activity of the Autonomic Nervous System, such as Heart Rate Variability, could help to provide reliable information on the mood and state of arousal of horses.
2017
1
19
23
GUIDI, ANDREA; LANATA', ANTONIO; VALENZA, GAETANO; SCILINGO, ENZO PASQUALE; BARAGLI, PAOLO
File in questo prodotto:
File Dimensione Formato  
JVEB_1002.pdf

Accesso chiuso

Dimensione 1.22 MB
Formato Adobe PDF
1.22 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1192134
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
social impact