The adoption of a short source-detector distance, combined with a time-resolved acquisition, can be advantageous in diffuse optical imaging due to the stricter spatial localization of the probing photons, provided that the strong burst of early photons is suppressed using a time-gated detection scheme. We propose a model for predicting the effect of the time-gated measurement system using a time-variant operator built on the system response acquired at different gate delays. The discrete representation of the system operator, termed Spread Matrix, can be analyzed to identify the bottlenecks of the detection system with respect to the physical problem under study. Measurements performed on tissue phantoms, using a time-gated single-photon avalanche diode and an interfiber distance of 2mm, demonstrate that inhomogeneities down to 3cm can be detected only if the decay constant of the detector is lower than 100ps, while the transient opening of the gate has a less critical impact.

Effects of time-gated detection in diffuse optical imaging at short source-detector separation / Contini D.; Mora A.D.; Spinelli L.; Farina A.; Torricelli A.; Cubeddu R.; Martelli F.; Zaccanti G.; Tosi A.; Boso G.; Zappa F.; Pifferi A.. - In: JOURNAL OF PHYSICS D. APPLIED PHYSICS. - ISSN 0022-3727. - ELETTRONICO. - 48:(2015), pp. 045401-1-045401-11. [10.1088/0022-3727/48/4/045401]

Effects of time-gated detection in diffuse optical imaging at short source-detector separation

Martelli F.
Membro del Collaboration Group
;
Zaccanti G.;Zappa F.;
2015

Abstract

The adoption of a short source-detector distance, combined with a time-resolved acquisition, can be advantageous in diffuse optical imaging due to the stricter spatial localization of the probing photons, provided that the strong burst of early photons is suppressed using a time-gated detection scheme. We propose a model for predicting the effect of the time-gated measurement system using a time-variant operator built on the system response acquired at different gate delays. The discrete representation of the system operator, termed Spread Matrix, can be analyzed to identify the bottlenecks of the detection system with respect to the physical problem under study. Measurements performed on tissue phantoms, using a time-gated single-photon avalanche diode and an interfiber distance of 2mm, demonstrate that inhomogeneities down to 3cm can be detected only if the decay constant of the detector is lower than 100ps, while the transient opening of the gate has a less critical impact.
48
045401-1
045401-11
Goal 3: Good health and well-being
Contini D.; Mora A.D.; Spinelli L.; Farina A.; Torricelli A.; Cubeddu R.; Martelli F.; Zaccanti G.; Tosi A.; Boso G.; Zappa F.; Pifferi A.
File in questo prodotto:
File Dimensione Formato  
Spread_MAtrix_0022-3727_48_4_045401.pdf

Accesso chiuso

Descrizione: Articolo principale
Tipologia: Pdf editoriale (Version of record)
Licenza: DRM non definito
Dimensione 1.02 MB
Formato Adobe PDF
1.02 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2158/1193232
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 33
social impact