Light is a powerful non-invasive tool that can be exploited to probe highly scattering media like biological tissues for different purposes, from the detection of brain activity to the characterization of cancer lesions. In the last decade, timedomain diffuse optics (TDDO) systems demonstrated improved sensitivity when using time-gated acquisition chains and short source-detector separations (Ï), both theoretically and experimentally. However, the sensitivity to localized absorption changes buried inside a diffusive medium strongly depends on many parameters such as: SDS, laser power, delay and width of the gating window, absorption and scattering properties of the medium, instrument response function (IRF) shape, etc. In particular, relevant effects due to slow tails in the IRF were noticed, with detrimental effects on performances. We present simulated experimental results based on the diffusion approximation of the Radiative Transfer Equation and the perturbation theory subjected to the Born approximation. To quantify the system sensitivity to deep (few cm) and localized absorption perturbations, we exploited contrast and contrast-to-noise ratio (CNR), which are internationally agreed on standardized figures of merit. The purpose of this study is to determine which parameters have the greatest impact on these figures of merit, thus also providing a range of best operative conditions. The study is composed by two main stages: the former is a comparison between simulations and measurements on tissue-mimicking phantom, while the latter is a broad simulation study in which all relevant parameters are tuned to determine optimal measurement conditions. This study essentially demonstrates that under the influence of the slow tails in the IRF, the use of a small SDS no longer corresponds to optimal contrast and CNR. This work sets the ground for future studies with next-generation of TDDO components, presently under development, providing useful hints on relevant features to which one should take care when designing TDDO components.

Study of optimal measurement conditions for time-domain diffuse optics systems / Behera A.; Di Sieno L.; Pifferi A.; Martelli F.; Dalla Mora A.. - ELETTRONICO. - 10685:(2018), pp. 1068514-1-1068514-8. ( Biophotonics: Photonic Solutions for Better Health Care VI 2018 fra 2018) [10.1117/12.2307370].

Study of optimal measurement conditions for time-domain diffuse optics systems

Martelli F.
Membro del Collaboration Group
;
2018

Abstract

Light is a powerful non-invasive tool that can be exploited to probe highly scattering media like biological tissues for different purposes, from the detection of brain activity to the characterization of cancer lesions. In the last decade, timedomain diffuse optics (TDDO) systems demonstrated improved sensitivity when using time-gated acquisition chains and short source-detector separations (Ï), both theoretically and experimentally. However, the sensitivity to localized absorption changes buried inside a diffusive medium strongly depends on many parameters such as: SDS, laser power, delay and width of the gating window, absorption and scattering properties of the medium, instrument response function (IRF) shape, etc. In particular, relevant effects due to slow tails in the IRF were noticed, with detrimental effects on performances. We present simulated experimental results based on the diffusion approximation of the Radiative Transfer Equation and the perturbation theory subjected to the Born approximation. To quantify the system sensitivity to deep (few cm) and localized absorption perturbations, we exploited contrast and contrast-to-noise ratio (CNR), which are internationally agreed on standardized figures of merit. The purpose of this study is to determine which parameters have the greatest impact on these figures of merit, thus also providing a range of best operative conditions. The study is composed by two main stages: the former is a comparison between simulations and measurements on tissue-mimicking phantom, while the latter is a broad simulation study in which all relevant parameters are tuned to determine optimal measurement conditions. This study essentially demonstrates that under the influence of the slow tails in the IRF, the use of a small SDS no longer corresponds to optimal contrast and CNR. This work sets the ground for future studies with next-generation of TDDO components, presently under development, providing useful hints on relevant features to which one should take care when designing TDDO components.
2018
Proceedings of SPIE - The International Society for Optical Engineering
Biophotonics: Photonic Solutions for Better Health Care VI 2018
fra
2018
Goal 3: Good health and well-being for people
Behera A.; Di Sieno L.; Pifferi A.; Martelli F.; Dalla Mora A.
File in questo prodotto:
File Dimensione Formato  
PhotonicsEurope_fulltext_free.pdf

Accesso chiuso

Descrizione: Articolo principale
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.87 MB
Formato Adobe PDF
1.87 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1193595
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact