The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. This protocol addresses the characteristic of optical brain imaging to detect, localize, and quantify absorption changes in the brain. It was implemented with two types of inhomogeneous liquid phantoms based on Intralipid and India ink with well-defined optical properties. First, small black inclusions were used to mimic localized changes of the absorption coefficient. The position of the inclusions was varied in depth and lateral direction to investigate contrast and spatial resolution. Second, two-layered liquid phantoms with variable absorption coefficients were employed to study the quantification of layer-wide changes and, in particular, to determine depth selectivity, i.e., the ratio of sensitivities for deep and superficial absorption changes. We introduce the tests of the nEUROPt protocol and present examples of results obtained with different instruments and methods of data analysis. This protocol could be a useful step toward performance tests for future standards in diffuse optical imaging. © The Authors.
Performance assessment of time-domain optical brain imagers, part 2: NEUROPt protocol / Wabnitz H.; Jelzow A.; Mazurenka M.; Steinkellner O.; MacDonald R.; Milej D.; Zolek N.; Kacprzak M.; Sawosz P.; Maniewski R.; Liebert A.; Magazov S.; Hebden J.; Martelli F.; Di Ninni P.; Zaccanti G.; Torricelli A.; Contini D.; Re R.; Zucchelli L.; Spinelli L.; Cubeddu R.; Pifferi A.. - In: JOURNAL OF BIOMEDICAL OPTICS. - ISSN 1083-3668. - ELETTRONICO. - 19:(2014), pp. 086012-1-086012-12. [10.1117/1.JBO.19.8.086012]
Performance assessment of time-domain optical brain imagers, part 2: NEUROPt protocol
Martelli F.Membro del Collaboration Group
;Di Ninni P.;Zaccanti G.;
2014
Abstract
The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. This protocol addresses the characteristic of optical brain imaging to detect, localize, and quantify absorption changes in the brain. It was implemented with two types of inhomogeneous liquid phantoms based on Intralipid and India ink with well-defined optical properties. First, small black inclusions were used to mimic localized changes of the absorption coefficient. The position of the inclusions was varied in depth and lateral direction to investigate contrast and spatial resolution. Second, two-layered liquid phantoms with variable absorption coefficients were employed to study the quantification of layer-wide changes and, in particular, to determine depth selectivity, i.e., the ratio of sensitivities for deep and superficial absorption changes. We introduce the tests of the nEUROPt protocol and present examples of results obtained with different instruments and methods of data analysis. This protocol could be a useful step toward performance tests for future standards in diffuse optical imaging. © The Authors.File | Dimensione | Formato | |
---|---|---|---|
Wabnitz_JBO_19_8_086012__performance_part 2_nEUROPt__JBO-140247PR_Final proof 1.pdf
Accesso chiuso
Descrizione: Articolo principale
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
1.93 MB
Formato
Adobe PDF
|
1.93 MB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.