In this work we studied the accuracy of a non-linear fitting procedure, based on the Levenberg-Marquardt algorithm, for time-resolved measurements to retrieve the absorption and the reduced scattering coefficients of an absorbing diffusive medium. This procedure is suitable for retrieving optical properties in a wider range of situations (e.g. solid samples, reflectance geometry), with respect to the linear inversion procedures recently presented for both CW and time domain measurements. By means of both analytical and numerical (Monte Carlo) simulations, we quantified the influence of photon counts, temporal sampling, analytical model, background and instrument response function on the accuracy in the estimation of the optical properties. Furthermore, we validated our results with preliminary measurements on calibrated diffusive solutions. The main source of error that affects the accuracy of the absorption and reduced scattering coefficients retrieved by the non-linear procedure appears to be the analytical model adopted in the inversion procedure. © 2009 SPIE-OSA.

Nonlinear fitting procedure for accurate time-resolved measurements in diffusive media / Spinelli L.; Martelli F.; Torricelli A.; Pifferi A.; Zaccanti G.. - In: PROGRESS IN BIOMEDICAL OPTICS AND IMAGING. - ISSN 1605-7422. - ELETTRONICO. - 7369:(2009), pp. 73691C-1-73691C-8. (Intervento presentato al convegno Diffuse Optical Imaging II tenutosi a Munich, deu nel 2009) [10.1117/12.831651].

Nonlinear fitting procedure for accurate time-resolved measurements in diffusive media

Martelli F.
Membro del Collaboration Group
;
Zaccanti G.
2009

Abstract

In this work we studied the accuracy of a non-linear fitting procedure, based on the Levenberg-Marquardt algorithm, for time-resolved measurements to retrieve the absorption and the reduced scattering coefficients of an absorbing diffusive medium. This procedure is suitable for retrieving optical properties in a wider range of situations (e.g. solid samples, reflectance geometry), with respect to the linear inversion procedures recently presented for both CW and time domain measurements. By means of both analytical and numerical (Monte Carlo) simulations, we quantified the influence of photon counts, temporal sampling, analytical model, background and instrument response function on the accuracy in the estimation of the optical properties. Furthermore, we validated our results with preliminary measurements on calibrated diffusive solutions. The main source of error that affects the accuracy of the absorption and reduced scattering coefficients retrieved by the non-linear procedure appears to be the analytical model adopted in the inversion procedure. © 2009 SPIE-OSA.
2009
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
Diffuse Optical Imaging II
Munich, deu
2009
Goal 3: Good health and well-being for people
Spinelli L.; Martelli F.; Torricelli A.; Pifferi A.; Zaccanti G.
File in questo prodotto:
File Dimensione Formato  
Nonlinear_Fitting_Procedure_.pdf

Accesso chiuso

Descrizione: Articolo principale
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 8.87 MB
Formato Adobe PDF
8.87 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1194715
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact