BACKGROUND: The aim of this paper is to report the first preliminary experience with intraoperative indocyanine green (ICG) fluorescence videography (IFV) to assess graft and ureteral reperfusion during robot-assisted kidney transplantation (RAKT). METHODS: We prospectively collected data from consecutive patients undergoing RAKT and IFV from living-donors at our Institution between January 2017 and April 2018. RAKT was performed following the principles of the Vattikuti-Medanta technique. ICG was injected intravenously after vascular anastomoses to quantitate graft and ureteral fluorescence signal. The signal intensity within selected intraoperative snapshots was evaluated for renal parenchyma, ureter and vascular anastomoses. A systematic review of the English-language literature about the topic was performed according to the PRISMA statement recommendations. RESULTS: Six patients were included. Neither conversions to open surgery nor major intra- or postoperative complications were recorded. At a median follow-up of 12 months (IQR 8-13), median estimated glomerular filtration rate was 64.2 mL/min/1.73 m 2 (IQR 45.3-98.4). Intraoperative quantitative assessment of ICG fluorescence was successful in all patients. Of the five studies selected by our review, mostly prospective studies, all including open KT series. Yet, most studies were limited by lack of quantitative measures of IFV fluorescence. CONCLUSIONS: IFV during RAKT is feasible and safe and provides a reliable assessment of graft reperfusion. Larger studies are needed to standardize the technique and to evaluate the association between fluorescence signal, ultrasound parameters and postoperative kidney function.

Intraoperative assessment of ureteral and graft reperfusion during robotic kidney transplantation with indocyanine green fluorescence videography / Vignolini G.; Sessa F.; Greco I.; Cito G.; Vanacore D.; Cocci A.; Sessa M.; Grandi V.; Pili A.; Giancane S.; Gacci M.; Sebastianelli A.; Li Marzi V.; Breda A.; Campi R.; Serni S.. - In: MINERVA UROLOGICA E NEFROLOGICA. - ISSN 0393-2249. - ELETTRONICO. - 71:(2019), pp. 79-84. [10.23736/S0393-2249.18.03278-2]

Intraoperative assessment of ureteral and graft reperfusion during robotic kidney transplantation with indocyanine green fluorescence videography

Vignolini G.;Sessa F.;Greco I.;Cito G.;Vanacore D.;Cocci A.;Sessa M.;Pili A.;Giancane S.;Gacci M.;Sebastianelli A.;Li Marzi V.;Campi R.;Serni S.
2019

Abstract

BACKGROUND: The aim of this paper is to report the first preliminary experience with intraoperative indocyanine green (ICG) fluorescence videography (IFV) to assess graft and ureteral reperfusion during robot-assisted kidney transplantation (RAKT). METHODS: We prospectively collected data from consecutive patients undergoing RAKT and IFV from living-donors at our Institution between January 2017 and April 2018. RAKT was performed following the principles of the Vattikuti-Medanta technique. ICG was injected intravenously after vascular anastomoses to quantitate graft and ureteral fluorescence signal. The signal intensity within selected intraoperative snapshots was evaluated for renal parenchyma, ureter and vascular anastomoses. A systematic review of the English-language literature about the topic was performed according to the PRISMA statement recommendations. RESULTS: Six patients were included. Neither conversions to open surgery nor major intra- or postoperative complications were recorded. At a median follow-up of 12 months (IQR 8-13), median estimated glomerular filtration rate was 64.2 mL/min/1.73 m 2 (IQR 45.3-98.4). Intraoperative quantitative assessment of ICG fluorescence was successful in all patients. Of the five studies selected by our review, mostly prospective studies, all including open KT series. Yet, most studies were limited by lack of quantitative measures of IFV fluorescence. CONCLUSIONS: IFV during RAKT is feasible and safe and provides a reliable assessment of graft reperfusion. Larger studies are needed to standardize the technique and to evaluate the association between fluorescence signal, ultrasound parameters and postoperative kidney function.
2019
71
79
84
Goal 3: Good health and well-being for people
Vignolini G.; Sessa F.; Greco I.; Cito G.; Vanacore D.; Cocci A.; Sessa M.; Grandi V.; Pili A.; Giancane S.; Gacci M.; Sebastianelli A.; Li Marzi V.; Breda A.; Campi R.; Serni S.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1207497
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact