In this paper the authors describe the development and the characterization of a Quartz Crystal Microbalance (QCM) sensor for N02 detection with the sensitive layer made of a thin films of poly (3,4-ethylenedioxythiophene) (PEDOT). The PEDOT layer was obtained by electropolymerization on one of the gold electrodes of a 10 MHz AT-cut commercial quartz crystal. The sensor performance in terms of sensitivity and selectivity were assessed exploiting an ad hoc chemical sampling unit, and a low noise conditioning and processing electronic system. This latter consists of an oscillator hosting the piezoelectric resonator, and of a frequency measurement system granting a (short time) relative accuracy of approximately 10-8 , which ensures a mass resolution in the order of the ng. The preliminary obtained results show a N02 resolution and sensitivity of the order of 1 ppm, and 2.6 Hz/ppm, respectively, at 35°C constant room temperature and in a dry environment, and show that a satisfactory repeatability can be achieved with recovery cycles in N2 at room temperature.

N02 QCM gas sensor based on electrochemical deposition of PEDOT / FortI A.; Innocenti M.; Foreste M.L.; Mugnaini M.; Pasquini I.; Pigani L.; Rocchil S.; Vignoli V.. - ELETTRONICO. - (2009), pp. 184-187. ( 3rd International Workshop on Advances in Sensors and Interfaces, IWASI 2009 Trani, ita 2009) [10.1109/IWASI.2009.5184792].

N02 QCM gas sensor based on electrochemical deposition of PEDOT

FortI A.;Innocenti M.;Vignoli V.
2009

Abstract

In this paper the authors describe the development and the characterization of a Quartz Crystal Microbalance (QCM) sensor for N02 detection with the sensitive layer made of a thin films of poly (3,4-ethylenedioxythiophene) (PEDOT). The PEDOT layer was obtained by electropolymerization on one of the gold electrodes of a 10 MHz AT-cut commercial quartz crystal. The sensor performance in terms of sensitivity and selectivity were assessed exploiting an ad hoc chemical sampling unit, and a low noise conditioning and processing electronic system. This latter consists of an oscillator hosting the piezoelectric resonator, and of a frequency measurement system granting a (short time) relative accuracy of approximately 10-8 , which ensures a mass resolution in the order of the ng. The preliminary obtained results show a N02 resolution and sensitivity of the order of 1 ppm, and 2.6 Hz/ppm, respectively, at 35°C constant room temperature and in a dry environment, and show that a satisfactory repeatability can be achieved with recovery cycles in N2 at room temperature.
2009
3rd International Workshop on Advances in Sensors and Interfaces, IWASI 2009
3rd International Workshop on Advances in Sensors and Interfaces, IWASI 2009
Trani, ita
Goal 9: Industry, Innovation, and Infrastructure
FortI A.; Innocenti M.; Foreste M.L.; Mugnaini M.; Pasquini I.; Pigani L.; Rocchil S.; Vignoli V.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1208490
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? ND
social impact