We report on the preliminary results obtained out of a wearable module designed to be encompassed within a ring-shaped system aimed at providing healthcare services. The module is composed of two sensors for the measuring of Galvanic Skin Response (GSR) and Heart Rate Variability (HRV). A first device validation was carried out by involving four subjects who were asked to perform tasks providing different stress-related statuses. A comparison of physiological parameters measured by the module with those measured by a commercial HRV-GSR sensor chosen as gold standard was made. Two out of the three HRV parameters and all of the GSR parameters measured with the module resulted consistent (mostly differing less than 10%) with the same parameters measured by the gold standard. The work reported in this paper set a milestone for the realization of a system exploiting sensor fusion to provide active ageing, stress detection, activity recognition and e-health services has been achieved.

Development of a Novel Wearable Ring-Shaped Biosensor / Santarelli, L.; Diyakonova, O.; Betti, S.; Esposito, D.; Castro, E.; Cavallo, F.. - ELETTRONICO. - 2018-:(2018), pp. 3750-3753. (Intervento presentato al convegno 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2018 tenutosi a Hawaii Convention Center, usa nel 2018) [10.1109/EMBC.2018.8513330].

Development of a Novel Wearable Ring-Shaped Biosensor

Castro, E.;Cavallo, F.
2018

Abstract

We report on the preliminary results obtained out of a wearable module designed to be encompassed within a ring-shaped system aimed at providing healthcare services. The module is composed of two sensors for the measuring of Galvanic Skin Response (GSR) and Heart Rate Variability (HRV). A first device validation was carried out by involving four subjects who were asked to perform tasks providing different stress-related statuses. A comparison of physiological parameters measured by the module with those measured by a commercial HRV-GSR sensor chosen as gold standard was made. Two out of the three HRV parameters and all of the GSR parameters measured with the module resulted consistent (mostly differing less than 10%) with the same parameters measured by the gold standard. The work reported in this paper set a milestone for the realization of a system exploiting sensor fusion to provide active ageing, stress detection, activity recognition and e-health services has been achieved.
2018
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2018
Hawaii Convention Center, usa
2018
Santarelli, L.; Diyakonova, O.; Betti, S.; Esposito, D.; Castro, E.; Cavallo, F.
File in questo prodotto:
File Dimensione Formato  
C050 - Development ring sensor.pdf

Accesso chiuso

Dimensione 280.99 kB
Formato Adobe PDF
280.99 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1210779
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact