Objective: The objectives of this paper are to develop and test the ability of a wearable physiological sensors system, based on ECG, EDA, and EEG, to capture human stress and to assess whether the detected changes in physiological signals correlate with changes in salivary cortisol level, which is a reliable, objective biomarker of stress. Methods: 15 healthy participants, eight males and seven females, mean age 40.8 ± 9.5 years, wore a set of three commercial sensors to record physiological signals during the Maastricht Acute Stress Test, an experimental protocol known to elicit robust physical and mental stress in humans. Salivary samples were collected throughout the different phases of the test. Statistical analysis was performed using a support vector machine (SVM) classification algorithm. A correlation analysis between extracted physiological features and salivary cortisol levels was also performed. Results: 15 features extracted from heart rate variability, electrodermal, and electroencephalography signals showed a high degree of significance in disentangling stress from a relaxed state. The classification algorithm, based on significant features, provided satisfactory outcomes with 86% accuracy. Furthermore, correlation analysis showed that the observed changes in physiological features were consistent with the trend of salivary cortisol levels (R2 = 0.714). Conclusion: The tested set of wearable sensors was able to successfully capture human stress and quantify stress level. Significance: The results of this pilot study may be useful in designing portable and remote control systems, such as medical devices used to turn on interventions and prevent stress consequences.

Evaluation of an integrated system of wearable physiological sensors for stress monitoring in working environments by using biological markers / Betti, Stefano; Lova, Raffaele Molino; Rovini, Erika; Acerbi, Giorgia; Santarelli, Luca; Cabiati, Manuela; Ry, Silvia Del; Cavallo, Filippo. - In: IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING. - ISSN 0018-9294. - STAMPA. - 65:(2018), pp. 1748-1758. [10.1109/TBME.2017.2764507]

Evaluation of an integrated system of wearable physiological sensors for stress monitoring in working environments by using biological markers

Rovini, Erika;Cavallo, Filippo
2018

Abstract

Objective: The objectives of this paper are to develop and test the ability of a wearable physiological sensors system, based on ECG, EDA, and EEG, to capture human stress and to assess whether the detected changes in physiological signals correlate with changes in salivary cortisol level, which is a reliable, objective biomarker of stress. Methods: 15 healthy participants, eight males and seven females, mean age 40.8 ± 9.5 years, wore a set of three commercial sensors to record physiological signals during the Maastricht Acute Stress Test, an experimental protocol known to elicit robust physical and mental stress in humans. Salivary samples were collected throughout the different phases of the test. Statistical analysis was performed using a support vector machine (SVM) classification algorithm. A correlation analysis between extracted physiological features and salivary cortisol levels was also performed. Results: 15 features extracted from heart rate variability, electrodermal, and electroencephalography signals showed a high degree of significance in disentangling stress from a relaxed state. The classification algorithm, based on significant features, provided satisfactory outcomes with 86% accuracy. Furthermore, correlation analysis showed that the observed changes in physiological features were consistent with the trend of salivary cortisol levels (R2 = 0.714). Conclusion: The tested set of wearable sensors was able to successfully capture human stress and quantify stress level. Significance: The results of this pilot study may be useful in designing portable and remote control systems, such as medical devices used to turn on interventions and prevent stress consequences.
2018
65
1748
1758
Betti, Stefano; Lova, Raffaele Molino; Rovini, Erika; Acerbi, Giorgia; Santarelli, Luca; Cabiati, Manuela; Ry, Silvia Del; Cavallo, Filippo
File in questo prodotto:
File Dimensione Formato  
IP031 - Evaluation of an integrated system of wearable physiological sensors.pdf

Accesso chiuso

Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1210821
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 140
  • ???jsp.display-item.citation.isi??? 98
social impact