INTRODUCTION: The impact on clinical outcomes of the metal coverage on the coronary surface (namely the metal-to-artery ratio) of currently used drug-eluting stents (DESs) has not been defined. METHODS: All patients with a left main or bifurcation stenosis treated with percutaneous coronary intervention (PCI) using ultrathin stents (struts thinner than 81 μm) were enrolled with a prospective multicentre fashion. The rate of device-oriented endpoint [DOE, defined as a composite of target lesion revascularization (TLR) and stent thrombosis] was the primary endpoint, while its single components were the secondary ones, evaluated according to the metal-to-artery ratio. RESULTS: After 14 ± 10.4 months 62 (7.5%) of 830 patients undergoing PCI on left main experienced a DOE without differences in the metal-to-artery ratio (14.5 ± 2.1 vs. 14.4 ± 1.9, P = 0.51). Fifty out (2.4%) of 2082 patients treated with PCI on a coronary bifurcation other than left main experienced a DOE, with a higher mean metal-to-artery ratio (15.3 ± 2.1 vs. 14.6 ± 2, P = 0.01). At multivariate analysis, together with hypertension and diabetes, the metal-to-artery ratio was an independent predictor of DOE (hazard ratio 1.7 : 1.02-1.34, P = 0.02) in nonleft main PCI. When analysed for diameter, we found a significant correlation with DOE when the stent diameter was inferior to 3.0 mm (hazard ratio 1.21: 1.06-1.38, P < 0.01, all 95% confidence interval); this result was mainly consistent for patients treated with provisional stenting. The metal-to-artery ratio does not impact on outcomes in left main PCI, both in the provisional or two-stent technique, and generally when a drug-eluting stent more than 3.5 mm in diameter is implanted. Regarding nonleft main PCI, it is independently related to DOE and TLR, especially for DES with a diameter of 3.25 mm or less. CONCLUSION: The metal-to-artery ratio does not impact on outcomes in left main PCI, both in the provisional or two-stent technique, and generally when a drug-eluting stent more than 3.5 mm in diameter is implanted. Regarding nonleft main PCI, it is independently related to DOE and TLR, especially for DES with a diameter of 3.25 mm or less.

Impact of the metal-to-artery ratio on clinical outcomes in left main and nonleft main bifurcation: insights the RAIN-CARDIOGROUP VII study (veRy thin stents for patients with left mAIn or bifurcatioN in real life) / Iannaccone M.; D'Ascenzo F.; Gatti P.; Cerrato E.; Nunez-Gil I.; Wojakowski W.; Capodanno D.; Figini F.; Wanha W.; Chieffo A.; De Ferrari G.M.; Di Mario C.. - In: JOURNAL OF CARDIOVASCULAR MEDICINE. - ISSN 1558-2035. - ELETTRONICO. - 21:(2020), pp. 669-674. [10.2459/JCM.0000000000001010]

Impact of the metal-to-artery ratio on clinical outcomes in left main and nonleft main bifurcation: insights the RAIN-CARDIOGROUP VII study (veRy thin stents for patients with left mAIn or bifurcatioN in real life)

Di Mario C.
2020

Abstract

INTRODUCTION: The impact on clinical outcomes of the metal coverage on the coronary surface (namely the metal-to-artery ratio) of currently used drug-eluting stents (DESs) has not been defined. METHODS: All patients with a left main or bifurcation stenosis treated with percutaneous coronary intervention (PCI) using ultrathin stents (struts thinner than 81 μm) were enrolled with a prospective multicentre fashion. The rate of device-oriented endpoint [DOE, defined as a composite of target lesion revascularization (TLR) and stent thrombosis] was the primary endpoint, while its single components were the secondary ones, evaluated according to the metal-to-artery ratio. RESULTS: After 14 ± 10.4 months 62 (7.5%) of 830 patients undergoing PCI on left main experienced a DOE without differences in the metal-to-artery ratio (14.5 ± 2.1 vs. 14.4 ± 1.9, P = 0.51). Fifty out (2.4%) of 2082 patients treated with PCI on a coronary bifurcation other than left main experienced a DOE, with a higher mean metal-to-artery ratio (15.3 ± 2.1 vs. 14.6 ± 2, P = 0.01). At multivariate analysis, together with hypertension and diabetes, the metal-to-artery ratio was an independent predictor of DOE (hazard ratio 1.7 : 1.02-1.34, P = 0.02) in nonleft main PCI. When analysed for diameter, we found a significant correlation with DOE when the stent diameter was inferior to 3.0 mm (hazard ratio 1.21: 1.06-1.38, P < 0.01, all 95% confidence interval); this result was mainly consistent for patients treated with provisional stenting. The metal-to-artery ratio does not impact on outcomes in left main PCI, both in the provisional or two-stent technique, and generally when a drug-eluting stent more than 3.5 mm in diameter is implanted. Regarding nonleft main PCI, it is independently related to DOE and TLR, especially for DES with a diameter of 3.25 mm or less. CONCLUSION: The metal-to-artery ratio does not impact on outcomes in left main PCI, both in the provisional or two-stent technique, and generally when a drug-eluting stent more than 3.5 mm in diameter is implanted. Regarding nonleft main PCI, it is independently related to DOE and TLR, especially for DES with a diameter of 3.25 mm or less.
2020
21
669
674
Goal 3: Good health and well-being for people
Iannaccone M.; D'Ascenzo F.; Gatti P.; Cerrato E.; Nunez-Gil I.; Wojakowski W.; Capodanno D.; Figini F.; Wanha W.; Chieffo A.; De Ferrari G.M.; Di Mar...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1215205
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact