Background: Calcific coronary lesions can be so resistant to prevent symmetric stent dilatation with high risk of ISR/thrombosis. The aim of the current study is to evaluate the safety and efficacy of super high-pressure dilatation (>30-to-45Atm) using a dedicated NC-balloon (OPN, SIS-Medical-AG, Winterthur-Switzerland). Methods: We retrospectively evaluated 326 consecutive undilatable lesions in which conventional NC-balloons failed to achieve adequate post-dilatation luminal gain. After the failed attempt an OPN-balloon was inflated up to achieve a uniform balloon expansion (maximal dilatation pressure of 45–50 Atm). Lesions were divided into two groups according to the final inflation pressure: Group-I: lesion responsive to 30-40Atm and Group-2:>40 Atm. Angiographic success was defined as residual angiographic stenosis<30% assessed by visual estimation with TIMI3-flow. Procedural success was defined as the achievement of angiographic success without any MACE. Results: Angiographic success was achieved in 97.5%, procedural success in 96.6%; 53% of the lesions were responsive to a slower inflation pressure (Group I) while in the remaining 47%, the optimal expansion required a pressure > 40ATM (Group II). In 3 patients coronary rupture occurred after balloon inflation and was successfully treated with stent implantation with a final TIMI3-flow. The OPN alone was able to achieve adequate expansion in >90%. 0.9% days MACE were reported. Conclusion: The OPN-dedicated high-pressure balloon provides an effective and safe strategy for treatment of severe resistant coronary lesions.
Clinical Experience with Very High-Pressure Dilatation for Resistant Coronary Lesions / Secco G.G.; Buettner A.; Parisi R.; Pistis G.; Vercellino M.; Audo A.; Kambis M.; Garbo R.; Porto I.; Tarantini G.; Di Mario C.. - In: CARDIOVASCULAR REVASCULARIZATION MEDICINE. - ISSN 1553-8389. - ELETTRONICO. - 20:(2019), pp. 1083-1087. [10.1016/j.carrev.2019.02.026]
Clinical Experience with Very High-Pressure Dilatation for Resistant Coronary Lesions
Di Mario C.
2019
Abstract
Background: Calcific coronary lesions can be so resistant to prevent symmetric stent dilatation with high risk of ISR/thrombosis. The aim of the current study is to evaluate the safety and efficacy of super high-pressure dilatation (>30-to-45Atm) using a dedicated NC-balloon (OPN, SIS-Medical-AG, Winterthur-Switzerland). Methods: We retrospectively evaluated 326 consecutive undilatable lesions in which conventional NC-balloons failed to achieve adequate post-dilatation luminal gain. After the failed attempt an OPN-balloon was inflated up to achieve a uniform balloon expansion (maximal dilatation pressure of 45–50 Atm). Lesions were divided into two groups according to the final inflation pressure: Group-I: lesion responsive to 30-40Atm and Group-2:>40 Atm. Angiographic success was defined as residual angiographic stenosis<30% assessed by visual estimation with TIMI3-flow. Procedural success was defined as the achievement of angiographic success without any MACE. Results: Angiographic success was achieved in 97.5%, procedural success in 96.6%; 53% of the lesions were responsive to a slower inflation pressure (Group I) while in the remaining 47%, the optimal expansion required a pressure > 40ATM (Group II). In 3 patients coronary rupture occurred after balloon inflation and was successfully treated with stent implantation with a final TIMI3-flow. The OPN alone was able to achieve adequate expansion in >90%. 0.9% days MACE were reported. Conclusion: The OPN-dedicated high-pressure balloon provides an effective and safe strategy for treatment of severe resistant coronary lesions.| File | Dimensione | Formato | |
|---|---|---|---|
|
1-s2.0-S1553838919301617-main.pdf
Accesso chiuso
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
313.62 kB
Formato
Adobe PDF
|
313.62 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



