Background: There are limited data regarding the impact of final kissing balloon (FKI) in patients treated with percutaneous coronary intervention using ultrathin stents in left main or bifurcations. Methods: All patients undergoing left main or bifurcations percutaneous coronary intervention enrolled in the RAIN registry (Very Thin Stents for Patients With MAIN or BiF in Real Life: The RAIN, a Multicenter Study) evaluating ultrathin stents were included. Major adverse cardiac event (a composite of all-cause death, myocardial infarction, target lesion revascularization, and stent thrombosis) was the primary end point, while its components, along with target vessel revascularization, were the secondary end points. The main analysis was performed comparing patients with and without FKI after adjustment with inverse probability of treatment weighting. Subgroup analyses were performed according to FKI (short [<3 mm] versus long overlap), strategy (provisional versus 2-stent), routine versus bail-out FKI, and the use of imaging and proximal optimization technique. Results: Two thousand seven hundred forty-two patients were included. At 16 months (8-20) follow-up, inverse probability of treatment weighting adjusted rates of major adverse cardiac event were similar between FKI and no-FKI group (15.1% versus 15.5%; P=0.967), this result did not change with use of imaging, proximal optimization technique, or routine versus bail-out FKI. In the 2-stent subgroup, FKI was associated with lower rates of target vessel revascularization (7.8% versus 15.9%; P=0.030) and target lesion revascularization (7.3% versus 15.2%; P=0.032). Short overlap FKI was associated with a lower rate of target lesion revascularization compared with no FKI (2.6% versus 5.4%; P=0.034), while long overlap was not (6.8% versus 5.4%; P=0.567). Conclusions: In patients with bifurcations or unprotected left main treated with ultrathin stents, short overlap FKI is associated with less restenosis. In a 2-stent strategy, FKI was associated with less target vessel revascularization and restenosis.

Impact of Kissing Balloon in Patients Treated with Ultrathin Stents for Left Main Lesions and Bifurcations: An Analysis from the RAIN-CARDIOGROUP VII Study / Gaido L.; D'ascenzo F.; Imori Y.; Wojakowski W.; Saglietto A.; Figini F.; Mattesini A.; Trabattoni D.; Rognoni A.; Tomassini F.; Bernardi A.; Ryan N.; Muscoli S.; Helft G.; De Filippo O.; Parma R.; De Luca L.; Ugo F.; Cerrato E.; Montefusco A.; Pennacchi M.; Wanha W.; Smolka G.; De Lio G.; Bruno F.; Huczek Z.; Boccuzzi G.; Cortese B.; Capodanno D.; Omede P.; Mancone M.; Nunez-Gil I.; Romeo F.; Varbella F.; Rinaldi M.; Escaned J.; Conrotto F.; Burzotta F.; Chieffo A.; Perl L.; D'amico M.; Di Mario C.; Sheiban I.; Gagnor A.; Giammaria M.; De Ferrari G.M.. - In: CIRCULATION. CARDIOVASCULAR INTERVENTIONS.. - ISSN 1941-7640. - ELETTRONICO. - 13:(2020), pp. 0-0. [10.1161/CIRCINTERVENTIONS.119.008325]

Impact of Kissing Balloon in Patients Treated with Ultrathin Stents for Left Main Lesions and Bifurcations: An Analysis from the RAIN-CARDIOGROUP VII Study

Di Mario C.;
2020

Abstract

Background: There are limited data regarding the impact of final kissing balloon (FKI) in patients treated with percutaneous coronary intervention using ultrathin stents in left main or bifurcations. Methods: All patients undergoing left main or bifurcations percutaneous coronary intervention enrolled in the RAIN registry (Very Thin Stents for Patients With MAIN or BiF in Real Life: The RAIN, a Multicenter Study) evaluating ultrathin stents were included. Major adverse cardiac event (a composite of all-cause death, myocardial infarction, target lesion revascularization, and stent thrombosis) was the primary end point, while its components, along with target vessel revascularization, were the secondary end points. The main analysis was performed comparing patients with and without FKI after adjustment with inverse probability of treatment weighting. Subgroup analyses were performed according to FKI (short [<3 mm] versus long overlap), strategy (provisional versus 2-stent), routine versus bail-out FKI, and the use of imaging and proximal optimization technique. Results: Two thousand seven hundred forty-two patients were included. At 16 months (8-20) follow-up, inverse probability of treatment weighting adjusted rates of major adverse cardiac event were similar between FKI and no-FKI group (15.1% versus 15.5%; P=0.967), this result did not change with use of imaging, proximal optimization technique, or routine versus bail-out FKI. In the 2-stent subgroup, FKI was associated with lower rates of target vessel revascularization (7.8% versus 15.9%; P=0.030) and target lesion revascularization (7.3% versus 15.2%; P=0.032). Short overlap FKI was associated with a lower rate of target lesion revascularization compared with no FKI (2.6% versus 5.4%; P=0.034), while long overlap was not (6.8% versus 5.4%; P=0.567). Conclusions: In patients with bifurcations or unprotected left main treated with ultrathin stents, short overlap FKI is associated with less restenosis. In a 2-stent strategy, FKI was associated with less target vessel revascularization and restenosis.
2020
13
0
0
Goal 3: Good health and well-being for people
Gaido L.; D'ascenzo F.; Imori Y.; Wojakowski W.; Saglietto A.; Figini F.; Mattesini A.; Trabattoni D.; Rognoni A.; Tomassini F.; Bernardi A.; Ryan N.;...espandi
File in questo prodotto:
File Dimensione Formato  
gaido-et-al-2020-impact-of-kissing-balloon-in-patients-treated-with-ultrathin-stents-for-left-main-lesions-and.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 783.24 kB
Formato Adobe PDF
783.24 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1216228
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 40
social impact