Focal ultrashort balloons are essential tools for lesion preparation and final stent expansion. However, they may cause a major distortion of the adjacent segments. Here we report a case with a stent deformation emphasizing the importance of utilizing intravascular imaging techniques for optimal interventions.

Stent deformation at the edge of a high pressure balloon / Kilic, Ismail Dogu; Foin, Nicolas; Konstantinidis, Nikolaos; Serdoz, Roberta; Caiazzo, Gianluca; Di Mario, Carlo. - In: CARDIOVASCULAR REVASCULARIZATION MEDICINE. - ISSN 1553-8389. - ELETTRONICO. - 16:(2015), pp. 508-509. [10.1016/j.carrev.2015.03.001]

Stent deformation at the edge of a high pressure balloon

Di Mario, Carlo
2015

Abstract

Focal ultrashort balloons are essential tools for lesion preparation and final stent expansion. However, they may cause a major distortion of the adjacent segments. Here we report a case with a stent deformation emphasizing the importance of utilizing intravascular imaging techniques for optimal interventions.
2015
16
508
509
Goal 3: Good health and well-being for people
Kilic, Ismail Dogu; Foin, Nicolas; Konstantinidis, Nikolaos; Serdoz, Roberta; Caiazzo, Gianluca; Di Mario, Carlo
File in questo prodotto:
File Dimensione Formato  
Kilic ID Cardiov Revasc Medicine 2015.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 463.72 kB
Formato Adobe PDF
463.72 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1216599
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact