Objectives: The aim of this study was to investigate the impact of patient and lesion complexity on outcomes with newer-generation zotarolimus-eluting stents (ZES) and everolimus-eluting stents (EES). Background: Clinical and angiographic outcomes of newer-generation stents have not been described among complex patients. Methods: Patients enrolled in the RESOLUTE All Comers trial (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) were stratified into "complex" and "simple." Results: Of 2,292 patients, 1,520 (66.3%) were complex and treated with ZES (n = 764) or EES (n = 756). Event rates were higher among complex patients, and results did not differ between ZES and EES, regardless of complexity. At 1 year, target lesion failure was 8.9% in ZES- and 9.7% in EES-treated complex patients (p = 0.66) and 6.8% in ZES- and 5.7% in EES-treated simple patients (p = 0.55). Rates of cardiac death (1.3% vs. 2.2%, p = 0.24), target-vessel myocardial infarction (4.3% vs. 4.4%, p = 0.90), and clinically indicated target lesion revascularization (4.4% vs. 4.0%, p = 0.80) were similar for both stent types among complex patients. Definite or probable stent thrombosis occurred in 20 (1.3%) complex patients with no difference between ZES (1.7%) and EES (0.9%, p = 0.26). Angiographic follow-up showed similar results for ZES and EES in terms of in-stent percentage diameter stenosis (22.2 ± 15.4% vs. 21.4 ± 15.8%, p = 0.67) and in-segment binary restenosis (6.6% vs. 8.0%, p = 0.82) in the complex group. Conclusions: In this all-comers randomized trial, major adverse cardiovascular events were more frequent among complex than simple patients. The newer-generation ZES and EES proved to be safe and effective, regardless of complexity, with similar clinical and angiographic outcomes for both stent types through 1 year. (RESOLUTE-III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention; NCT00617084) © 2011 American College of Cardiology Foundation.

The impact of patient and lesion complexity on clinical and angiographic outcomes after revascularization with zotarolimus- and everolimus-eluting stents: A substudy of the RESOLUTE all comers trial (a randomized comparison of a zotarolimus-eluting stent with an everolimus-eluting stent for percutaneous coronary intervention) / Stefanini G.G.; Serruys P.W.; Silber S.; Khattab A.A.; Van Geuns R.J.; Richardt G.; Buszman P.E.; Kelbaek H.; Van Boven A.J.; Hofma S.H.; Linke A.; Klauss V.; Wijns W.; MacAya C.; Garot P.; Di Mario C.; Manoharan G.; Kornowski R.; Ischinger T.; Bartorelli A.L.; Gobbens P.; Windecker S.. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - ELETTRONICO. - 57:(2011), pp. 2221-2232. [10.1016/j.jacc.2011.01.036]

The impact of patient and lesion complexity on clinical and angiographic outcomes after revascularization with zotarolimus- and everolimus-eluting stents: A substudy of the RESOLUTE all comers trial (a randomized comparison of a zotarolimus-eluting stent with an everolimus-eluting stent for percutaneous coronary intervention)

Di Mario C.;
2011

Abstract

Objectives: The aim of this study was to investigate the impact of patient and lesion complexity on outcomes with newer-generation zotarolimus-eluting stents (ZES) and everolimus-eluting stents (EES). Background: Clinical and angiographic outcomes of newer-generation stents have not been described among complex patients. Methods: Patients enrolled in the RESOLUTE All Comers trial (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) were stratified into "complex" and "simple." Results: Of 2,292 patients, 1,520 (66.3%) were complex and treated with ZES (n = 764) or EES (n = 756). Event rates were higher among complex patients, and results did not differ between ZES and EES, regardless of complexity. At 1 year, target lesion failure was 8.9% in ZES- and 9.7% in EES-treated complex patients (p = 0.66) and 6.8% in ZES- and 5.7% in EES-treated simple patients (p = 0.55). Rates of cardiac death (1.3% vs. 2.2%, p = 0.24), target-vessel myocardial infarction (4.3% vs. 4.4%, p = 0.90), and clinically indicated target lesion revascularization (4.4% vs. 4.0%, p = 0.80) were similar for both stent types among complex patients. Definite or probable stent thrombosis occurred in 20 (1.3%) complex patients with no difference between ZES (1.7%) and EES (0.9%, p = 0.26). Angiographic follow-up showed similar results for ZES and EES in terms of in-stent percentage diameter stenosis (22.2 ± 15.4% vs. 21.4 ± 15.8%, p = 0.67) and in-segment binary restenosis (6.6% vs. 8.0%, p = 0.82) in the complex group. Conclusions: In this all-comers randomized trial, major adverse cardiovascular events were more frequent among complex than simple patients. The newer-generation ZES and EES proved to be safe and effective, regardless of complexity, with similar clinical and angiographic outcomes for both stent types through 1 year. (RESOLUTE-III All Comers Trial: A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention; NCT00617084) © 2011 American College of Cardiology Foundation.
2011
57
2221
2232
Goal 3: Good health and well-being for people
Stefanini G.G.; Serruys P.W.; Silber S.; Khattab A.A.; Van Geuns R.J.; Richardt G.; Buszman P.E.; Kelbaek H.; Van Boven A.J.; Hofma S.H.; Linke A.; Kl...espandi
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0735109711012253-main.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 678.13 kB
Formato Adobe PDF
678.13 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1216724
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 103
  • ???jsp.display-item.citation.isi??? 90
social impact