This study compares the performance of two coil configurations for W-band pulsed ENDOR using a setup with both a radiofrequency ‘hairpin’ coil internal to a microwave non-radiative resonator and Helmholtz-like coils external to the resonator. Evaluation of the different coil performances is achieved via the ENDOR study of two model systems. The efficiencies of the coil configurations are first investigated numerically, showing that a higher radiofrequency current-to-magnetic field conversion factor can be achieved with the intra-cavity coil, with a similar radiofrequency magnetic field uniformity. This result is then confirmed by the broadband ENDOR spectra acquired with the two coil arrangements. A gain in the signal-to-noise ratio enabled by the internal coil of about a factor 10 was observed. In some cases, the high conversion factor of the intra-cavity coil led to a saturation of the ENDOR transitions. The possibility to implement a similar intra-cavity radiofrequency coil configuration in higher field spectrometers is finally discussed.

High-Field Pulsed ENDOR with Intra-cavity Radiofrequency Coil / Annino G.; Moons H.; Fittipaldi M.; Van Doorslaer S.; Goovaerts E.. - In: APPLIED MAGNETIC RESONANCE. - ISSN 0937-9347. - ELETTRONICO. - 51:(2020), pp. 1433-1449. [10.1007/s00723-020-01269-z]

High-Field Pulsed ENDOR with Intra-cavity Radiofrequency Coil

Fittipaldi M.;
2020

Abstract

This study compares the performance of two coil configurations for W-band pulsed ENDOR using a setup with both a radiofrequency ‘hairpin’ coil internal to a microwave non-radiative resonator and Helmholtz-like coils external to the resonator. Evaluation of the different coil performances is achieved via the ENDOR study of two model systems. The efficiencies of the coil configurations are first investigated numerically, showing that a higher radiofrequency current-to-magnetic field conversion factor can be achieved with the intra-cavity coil, with a similar radiofrequency magnetic field uniformity. This result is then confirmed by the broadband ENDOR spectra acquired with the two coil arrangements. A gain in the signal-to-noise ratio enabled by the internal coil of about a factor 10 was observed. In some cases, the high conversion factor of the intra-cavity coil led to a saturation of the ENDOR transitions. The possibility to implement a similar intra-cavity radiofrequency coil configuration in higher field spectrometers is finally discussed.
2020
51
1433
1449
Goal 9: Industry, Innovation, and Infrastructure
Annino G.; Moons H.; Fittipaldi M.; Van Doorslaer S.; Goovaerts E.
File in questo prodotto:
File Dimensione Formato  
Annino2020_Article_High-FieldPulsedENDORWithIntra.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 2.06 MB
Formato Adobe PDF
2.06 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1217106
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact