The objective of this study was to evaluate the spatial distribution of the variables bed temperature and humidity in compost dairy barn (CBP) with different ventilation systems. The facilities presented wood sawdust as bed material. The CBPs were divided into meshes with 40 equidistant points, in which the bed temperature levels were manually collected on the surface (tc-sup) and at a depth of 0.20 m (tc-20), as well as bed samples at both depths, which were used to determine moisture (Uc). The geostatistical technique was used to evaluate dependence and spatial distribution. The results showed the occurrence of dependence and spatial variability, and the lowest levels were verified for installation with HVLS ventilation. The results obtained allow us to conclude that ventilation influences the variables analyzed.
Temperatura e umidade da cama em instalações Compost Barn com diferentes sistemas de ventilação / Carlos Eduardo Alves Oliveira, Flávio Alves Damasceno, Gabriel Araújo E Silva Ferraz, João Antônio Costa Do Nascimentos, Rafaella Resende Andrade, Matteo Barbari. - ELETTRONICO. - (2020), pp. 1-10. (Intervento presentato al convegno XLIX Congresso Brasileiro de Engenharia Agrícola - CONBEA 2020 tenutosi a on-line nel 25-27 novembre 2020).
Temperatura e umidade da cama em instalações Compost Barn com diferentes sistemas de ventilação
Matteo Barbari
2020
Abstract
The objective of this study was to evaluate the spatial distribution of the variables bed temperature and humidity in compost dairy barn (CBP) with different ventilation systems. The facilities presented wood sawdust as bed material. The CBPs were divided into meshes with 40 equidistant points, in which the bed temperature levels were manually collected on the surface (tc-sup) and at a depth of 0.20 m (tc-20), as well as bed samples at both depths, which were used to determine moisture (Uc). The geostatistical technique was used to evaluate dependence and spatial distribution. The results showed the occurrence of dependence and spatial variability, and the lowest levels were verified for installation with HVLS ventilation. The results obtained allow us to conclude that ventilation influences the variables analyzed.File | Dimensione | Formato | |
---|---|---|---|
2020_-_Publicacao_-_XLIX_CONBEA_-_Temperatura_e_umidade_da_cama_em_instalacoes_CBP_com_diferentes_sistemas_de_ventilacao.pdf
accesso aperto
Descrizione: Pubblicazione finale
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
516.46 kB
Formato
Adobe PDF
|
516.46 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.