Background: Cardiac resynchronization therapy (CRT) reduces mortality and hospitalizations; it is debated whether CRT alone (CRT-P) or CRT plus defibrillator (CRT-D) is preferable, and still guidelines are not exhaustive. The aim of the study was to investigate whether to implant CRT-P or CRT-D in CRT-D patients who did not experience malignant arrhythmias at moment of replacement. Methods: Out of 451 heart failure patients undergoing CRT-D according to guidelines, 103 (67±10 years, 80% men) underwent device replacement with CRT-D. Every 6 months patients underwent to clinical evaluation and device interrogation and episodes of ventricular arrhythmias (VA) stored. At baseline and before replacement echocardiogram was performed. Patients were defined responders if left ventricular (LV) end-systolic volume decreased ≥15% and super-responders if LV ejection fraction increased ≥40% or ≥50%. Results: Mean follow-up was 75±24 months after implantation and 26±10 months after replacement. First VAs incidence per year did not decrease over time (p=0.619). Before replacement, 27 patients (26.2%, 15 responders/12 non-responders) experienced VA. After replacement, 8 patients (7.7%, 4 responders/4 non-responders) experienced VA for the first time. Super-responder condition was not associated with lower VA incidence before (=0.499) and after (p=0.339) replacement. At multivariate analysis, age was the only independent predictor of electrical appropriate therapy after substitution (ORper year =1.17; CI 95%= 1.03- 1.34; p=0.003). Conclusions: Freedom from VA before device replacement does not correlate with freedom from VA after replacement, so downgrade from CRT-D to CRT-P is not feasible at replacement, in particular in the elderlies, independently of responder and super-responder condition.

Incidence of ventricular arrhythmias after biventricular defibrillator replacement: impact on safety of downgrading from CRT-D to CRT-P / Nesti, Martina; Riccciardi, Giuseppe; Pieragnoli, Paolo; Fumagalli, Stefano; Padeletti, Margherita; Paoletti Perini, Alessandro; Cavarretta, Elena; Sciarra, Luigi. - In: MINERVA CARDIOANGIOLOGICA. - ISSN 1827-1618. - ELETTRONICO. - (2020), pp. 0-0. [10.23736/S0026-4725.20.05352-9]

Incidence of ventricular arrhythmias after biventricular defibrillator replacement: impact on safety of downgrading from CRT-D to CRT-P

Nesti, Martina;Pieragnoli, Paolo;Fumagalli, Stefano;Padeletti, Margherita;
2020

Abstract

Background: Cardiac resynchronization therapy (CRT) reduces mortality and hospitalizations; it is debated whether CRT alone (CRT-P) or CRT plus defibrillator (CRT-D) is preferable, and still guidelines are not exhaustive. The aim of the study was to investigate whether to implant CRT-P or CRT-D in CRT-D patients who did not experience malignant arrhythmias at moment of replacement. Methods: Out of 451 heart failure patients undergoing CRT-D according to guidelines, 103 (67±10 years, 80% men) underwent device replacement with CRT-D. Every 6 months patients underwent to clinical evaluation and device interrogation and episodes of ventricular arrhythmias (VA) stored. At baseline and before replacement echocardiogram was performed. Patients were defined responders if left ventricular (LV) end-systolic volume decreased ≥15% and super-responders if LV ejection fraction increased ≥40% or ≥50%. Results: Mean follow-up was 75±24 months after implantation and 26±10 months after replacement. First VAs incidence per year did not decrease over time (p=0.619). Before replacement, 27 patients (26.2%, 15 responders/12 non-responders) experienced VA. After replacement, 8 patients (7.7%, 4 responders/4 non-responders) experienced VA for the first time. Super-responder condition was not associated with lower VA incidence before (=0.499) and after (p=0.339) replacement. At multivariate analysis, age was the only independent predictor of electrical appropriate therapy after substitution (ORper year =1.17; CI 95%= 1.03- 1.34; p=0.003). Conclusions: Freedom from VA before device replacement does not correlate with freedom from VA after replacement, so downgrade from CRT-D to CRT-P is not feasible at replacement, in particular in the elderlies, independently of responder and super-responder condition.
2020
0
0
Nesti, Martina; Riccciardi, Giuseppe; Pieragnoli, Paolo; Fumagalli, Stefano; Padeletti, Margherita; Paoletti Perini, Alessandro; Cavarretta, Elena; Sciarra, Luigi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1219166
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact