Background: We evaluated the psychometric proprieties of the Screening for Aphasia in NeuroDegeneration (SAND) battery in Italian primary progressive aphasia (PPA) and movement disorder (MD) patients. Methods: The sample included 30 consecutive PPA and 45 MD patients who completed the SAND battery together with a clinical interview and a neurological/neuropsychological examination and 130 healthy controls (HC). Results: The SAND battery showed good internal consistency and good convergent and divergent validity. receiver operating characteristic analysis revealed an area under the curve of 0.978 for PPA versus HC and of 0.786 for PPA versus MD. A cutoff ≥3 gave a sensitivity of 0.933% and a specificity of 0.946% for discriminating PPA versus HC, whereas a cutoff ≥5 gave a sensitivity of 0.767% and a specificity of 0.667% for discriminating PPA versus MD. Conclusion: These results indicate that the SAND battery is an adequate, reliable, and valid diagnostic tool for PPA.
Screening for aphasia in neurodegeneration for the diagnosis of patients with primary progressive aphasia: Clinical validity and psychometric properties / Battista P.; Catricala E.; Piccininni M.; Copetti M.; Esposito V.; Polito C.; Miozzo A.; Gobbi E.; Cuoco S.; Boschi V.; Picillo M.; Sorbi S.; Barone P.; Iannaccone S.; Garrard P.; Logroscino G.; Cappa S.F.. - In: DEMENTIA AND GERIATRIC COGNITIVE DISORDERS. - ISSN 1420-8008. - STAMPA. - 46:(2018), pp. 243-252. [10.1159/000492632]
Screening for aphasia in neurodegeneration for the diagnosis of patients with primary progressive aphasia: Clinical validity and psychometric properties
Polito C.;Sorbi S.;Barone P.;
2018
Abstract
Background: We evaluated the psychometric proprieties of the Screening for Aphasia in NeuroDegeneration (SAND) battery in Italian primary progressive aphasia (PPA) and movement disorder (MD) patients. Methods: The sample included 30 consecutive PPA and 45 MD patients who completed the SAND battery together with a clinical interview and a neurological/neuropsychological examination and 130 healthy controls (HC). Results: The SAND battery showed good internal consistency and good convergent and divergent validity. receiver operating characteristic analysis revealed an area under the curve of 0.978 for PPA versus HC and of 0.786 for PPA versus MD. A cutoff ≥3 gave a sensitivity of 0.933% and a specificity of 0.946% for discriminating PPA versus HC, whereas a cutoff ≥5 gave a sensitivity of 0.767% and a specificity of 0.667% for discriminating PPA versus MD. Conclusion: These results indicate that the SAND battery is an adequate, reliable, and valid diagnostic tool for PPA.I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.