Background: In the emergency department (ED) definitive diagnosis of SARS-COV-2 pneumonia is challenging as nasopharyngeal swab (NPS) can give false negative results. Strategies to reduce false negative rate of NPS have limitations. Serial NPSs (24–48 h from one another) are time-consuming, sputum can not be collected in the majority of patients, and bronchoalveolar lavage (BAL), the most sensitive test, requires specific expertise. Laryngotracheal aspiration (LTA) is easy to perform and showed a similar accuracy to BAL for diagnosis of other pulmonary diseases, however it was not studied to diagnose SARS-COV-2 pneumonia. Objective: An observational cross-sectional study was performed to evaluate the negative predictive value of LTA in patients with suspected SARS-COV-2 pneumonia despite a negative NPS. Methods: In the EDs of two university hospitals, consecutive patients with suspected SARS-COV-2 pneumonia despite a negative NPS underwent LTA performed with a nasotracheal tube connected to a vacuum system. Final diagnosis based on all respiratory specimen tests (NPS, LTA and BAL) and hospital data was established by two reviewers and in case of discordance by a third reviewer. Results: 117 patients were enrolled. LTA was feasible in all patients and no patients experienced adverse events. Fifteen (12.7%) patients were diagnosed with community-acquired SARS-COV-2 pneumonia: 13 LTA positive and only 2 (1.7%) LTA negative. The negative predictive value of NPS and LTA was 87.3% (79.9% – 92.7%) and 98.1% (93.3.8%) respectively. Conclusions: LTA resulted feasible, safe and reduced false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative NPS.
Laryngotracheal aspiration test reduce the false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative nasopharyngeal swab / Nazerian P.; Sacco R.M.; Solbiati M.; Targetti E.; Marta C.; Blasi F.; Casazza G.; Colao M.G.; Tomassetti S.; Grifoni S.; Rossolini G.M.; Costantino G.. - In: EUROPEAN JOURNAL OF INTERNAL MEDICINE. - ISSN 0953-6205. - ELETTRONICO. - (2021), pp. 0-0. [10.1016/j.ejim.2021.06.019]
Laryngotracheal aspiration test reduce the false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative nasopharyngeal swab
Nazerian P.;Blasi F.;Tomassetti S.;Grifoni S.;Rossolini G. M.;
2021
Abstract
Background: In the emergency department (ED) definitive diagnosis of SARS-COV-2 pneumonia is challenging as nasopharyngeal swab (NPS) can give false negative results. Strategies to reduce false negative rate of NPS have limitations. Serial NPSs (24–48 h from one another) are time-consuming, sputum can not be collected in the majority of patients, and bronchoalveolar lavage (BAL), the most sensitive test, requires specific expertise. Laryngotracheal aspiration (LTA) is easy to perform and showed a similar accuracy to BAL for diagnosis of other pulmonary diseases, however it was not studied to diagnose SARS-COV-2 pneumonia. Objective: An observational cross-sectional study was performed to evaluate the negative predictive value of LTA in patients with suspected SARS-COV-2 pneumonia despite a negative NPS. Methods: In the EDs of two university hospitals, consecutive patients with suspected SARS-COV-2 pneumonia despite a negative NPS underwent LTA performed with a nasotracheal tube connected to a vacuum system. Final diagnosis based on all respiratory specimen tests (NPS, LTA and BAL) and hospital data was established by two reviewers and in case of discordance by a third reviewer. Results: 117 patients were enrolled. LTA was feasible in all patients and no patients experienced adverse events. Fifteen (12.7%) patients were diagnosed with community-acquired SARS-COV-2 pneumonia: 13 LTA positive and only 2 (1.7%) LTA negative. The negative predictive value of NPS and LTA was 87.3% (79.9% – 92.7%) and 98.1% (93.3.8%) respectively. Conclusions: LTA resulted feasible, safe and reduced false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative NPS.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0953620521002302-main.pdf
Accesso chiuso
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Tutti i diritti riservati
Dimensione
349.55 kB
Formato
Adobe PDF
|
349.55 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.