Objective: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0–3) for tophus, double contour and aggregates. Furthermore, the intra- and inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. Methods: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. Results: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (κ-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (κ-values 0.74–0.80) than inter-reader reliabilities (κ-values 0.61–0.67). Conclusion: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was developed with good inter- and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients.

Consensus-based semi-quantitative ultrasound scoring system for gout lesions: Results of an OMERACT Delphi process and web-reliability exercise / Christiansen S.N.; Filippou G.; Scire C.A.; Balint P.V.; Bruyn G.A.; Dalbeth N.; Dejaco C.; Sedie A.D.; Filippucci E.; Hammer H.B.; Iagnocco A.; Keen H.I.; Kissin E.Y.; Koski J.; Mandl P.; Martin J.; Miguel E.D.; Moller I.; Naredo E.; Pineda C.; Schmidt W.A.; Stewart S.; Antonietta D'Agostino M.; Terslev L.. - In: SEMINARS IN ARTHRITIS AND RHEUMATISM. - ISSN 0049-0172. - STAMPA. - 51:(2021), pp. 644-649. [10.1016/j.semarthrit.2020.11.011]

Consensus-based semi-quantitative ultrasound scoring system for gout lesions: Results of an OMERACT Delphi process and web-reliability exercise

Filippou G.;
2021

Abstract

Objective: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0–3) for tophus, double contour and aggregates. Furthermore, the intra- and inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. Methods: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. Results: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (κ-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (κ-values 0.74–0.80) than inter-reader reliabilities (κ-values 0.61–0.67). Conclusion: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was developed with good inter- and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients.
2021
51
644
649
Christiansen S.N.; Filippou G.; Scire C.A.; Balint P.V.; Bruyn G.A.; Dalbeth N.; Dejaco C.; Sedie A.D.; Filippucci E.; Hammer H.B.; Iagnocco A.; Keen H.I.; Kissin E.Y.; Koski J.; Mandl P.; Martin J.; Miguel E.D.; Moller I.; Naredo E.; Pineda C.; Schmidt W.A.; Stewart S.; Antonietta D'Agostino M.; Terslev L.
File in questo prodotto:
File Dimensione Formato  
073 - Christiansen et al. - 2021 - Consensus-based semi-quantitative ultrasound scori.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 1.28 MB
Formato Adobe PDF
1.28 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1245785
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 14
social impact