Objectives: A panoramic radiograph (PAN) is the most frequently diagnostic imaging technique carried out in dentistry and oral surgery. The correct performance of image acquisition is crucial to obtain adequate image quality. The aim of the present study is to (i) review the principles of PAN image acquisition and (ii) describe positioning errors and artefacts that may affect PAN image quality. Methods: Articles regarding PAN acquisition principles, patient’s positioning errors, artefacts, and image quality were retrieved from the literature. Results: Head orientation is of the utmost importance in guaranteeing correct image acquisition. Symmetry, occlusal plane inclination, mandibular condyles localization, cervical spine position, aspect of upper teeth root apexes, exposure parameters, and metal and motion artefacts are factors that greatly affect the image quality of a successful PAN. Conclusions: Several factors are the basis for PAN performance; therefore, a systematic approach that takes into account correct patient positioning and preparation is strongly suggested to improve overall examination quality.

Basic knowledge and new advances in panoramic radiography imaging techniques: A narrative review on what dentists and radiologists should know / Izzetti R.; Nisi M.; Aringhieri G.; Crocetti L.; Graziani F.; Nardi C.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - ELETTRONICO. - 11:(2021), pp. 7858-7871. [10.3390/app11177858]

Basic knowledge and new advances in panoramic radiography imaging techniques: A narrative review on what dentists and radiologists should know

Nardi C.
2021

Abstract

Objectives: A panoramic radiograph (PAN) is the most frequently diagnostic imaging technique carried out in dentistry and oral surgery. The correct performance of image acquisition is crucial to obtain adequate image quality. The aim of the present study is to (i) review the principles of PAN image acquisition and (ii) describe positioning errors and artefacts that may affect PAN image quality. Methods: Articles regarding PAN acquisition principles, patient’s positioning errors, artefacts, and image quality were retrieved from the literature. Results: Head orientation is of the utmost importance in guaranteeing correct image acquisition. Symmetry, occlusal plane inclination, mandibular condyles localization, cervical spine position, aspect of upper teeth root apexes, exposure parameters, and metal and motion artefacts are factors that greatly affect the image quality of a successful PAN. Conclusions: Several factors are the basis for PAN performance; therefore, a systematic approach that takes into account correct patient positioning and preparation is strongly suggested to improve overall examination quality.
2021
11
7858
7871
Izzetti R.; Nisi M.; Aringhieri G.; Crocetti L.; Graziani F.; Nardi C.
File in questo prodotto:
File Dimensione Formato  
OPT Narrative Review - AS.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 7.99 MB
Formato Adobe PDF
7.99 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1252399
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 18
social impact