Purpose: This retrospective work aims to evaluate the possible impact on intra- and inter-observer variability, contouring time, and contour accuracy of introducing a pelvis computed tomography (CT) auto-segmentation tool in radiotherapy planning workflow. Methods: Tests were carried out on five structures (bladder, rectum, pelvic lymph-nodes, and femoral heads) of six previously treated subjects, enrolling five radiation oncologists (ROs) to manually re-contour and edit auto-contours generated with a male pelvis CT atlas created with the commercial software MIM MAESTRO. The ROs first delineated manual contours (M). Then they modified the auto-contours, producing automatic-modified (AM) contours. The procedure was repeated to evaluate intra-observer variability, producing M1, M2, AM1, and AM2 contour sets (each comprising 5 structures × 6 test patients × 5 ROs = 150 contours), for a total of 600 contours. Potential time savings was evaluated by comparing contouring and editing times. Structure contours were compared to a reference standard by means of Dice similarity coefficient (DSC) and mean distance to agreement (MDA), to assess intra- and inter-observer variability. To exclude any automation bias, ROs evaluated both M and AM sets as “clinically acceptable” or “to be corrected” in a blind test. Results: Comparing AM to M sets, a significant reduction of both inter-observer variability (p < 0.001) and contouring time (-45% whole pelvis, p < 0.001) was obtained. Intra-observer variability reduction was significant only for bladder and femoral heads (p < 0.001). The statistical test showed no significant bias. Conclusion: Our atlas-based workflow proved to be effective for clinical practice as it can improve contour reproducibility and generate time savings. Based on these findings, institutions are encouraged to implement their auto-segmentation method.

Clinical validation of an automatic atlas-based segmentation tool for male pelvis CT images / Casati M.; Piffer S.; Calusi S.; Marrazzo L.; Simontacchi G.; Di Cataldo V.; Greto D.; Desideri I.; Vernaleone M.; Francolini G.; Livi L.; Pallotta S.. - In: JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS. - ISSN 1526-9914. - STAMPA. - (2022), pp. e13507-e13507. [10.1002/acm2.13507]

Clinical validation of an automatic atlas-based segmentation tool for male pelvis CT images

Casati M.;Piffer S.;Calusi S.;Marrazzo L.;Simontacchi G.;Greto D.;Desideri I.;Vernaleone M.;Francolini G.;Livi L.;Pallotta S.
2022

Abstract

Purpose: This retrospective work aims to evaluate the possible impact on intra- and inter-observer variability, contouring time, and contour accuracy of introducing a pelvis computed tomography (CT) auto-segmentation tool in radiotherapy planning workflow. Methods: Tests were carried out on five structures (bladder, rectum, pelvic lymph-nodes, and femoral heads) of six previously treated subjects, enrolling five radiation oncologists (ROs) to manually re-contour and edit auto-contours generated with a male pelvis CT atlas created with the commercial software MIM MAESTRO. The ROs first delineated manual contours (M). Then they modified the auto-contours, producing automatic-modified (AM) contours. The procedure was repeated to evaluate intra-observer variability, producing M1, M2, AM1, and AM2 contour sets (each comprising 5 structures × 6 test patients × 5 ROs = 150 contours), for a total of 600 contours. Potential time savings was evaluated by comparing contouring and editing times. Structure contours were compared to a reference standard by means of Dice similarity coefficient (DSC) and mean distance to agreement (MDA), to assess intra- and inter-observer variability. To exclude any automation bias, ROs evaluated both M and AM sets as “clinically acceptable” or “to be corrected” in a blind test. Results: Comparing AM to M sets, a significant reduction of both inter-observer variability (p < 0.001) and contouring time (-45% whole pelvis, p < 0.001) was obtained. Intra-observer variability reduction was significant only for bladder and femoral heads (p < 0.001). The statistical test showed no significant bias. Conclusion: Our atlas-based workflow proved to be effective for clinical practice as it can improve contour reproducibility and generate time savings. Based on these findings, institutions are encouraged to implement their auto-segmentation method.
2022
e13507
e13507
Casati M.; Piffer S.; Calusi S.; Marrazzo L.; Simontacchi G.; Di Cataldo V.; Greto D.; Desideri I.; Vernaleone M.; Francolini G.; Livi L.; Pallotta S....espandi
File in questo prodotto:
File Dimensione Formato  
2021 Clinical validation of an automatic atlas-based segmentation tool for male pelvis CT images.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 5.19 MB
Formato Adobe PDF
5.19 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1256117
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact