Diamond has a potential for dosimetry in advanced radiotherapy techniques, being a solid-state nearly tissue equivalent material, with the possibility to be grown in large diameter wafers by Chemical Vapour Deposition (CVD). A largearea bidimensional dosimeter made of up to two detector-grade adjacent 2.5×2.5cm2 polycrystalline Chemical Vapour Deposited (pCVD) diamond samples, each equipped with a 12×12 matrix of contacts and connected to a custom-made electronic read-out system, has been manufactured in view to achieve fast dynamics as well as spatial and time resolutions required in advanced radiotherapic techniques, such as Volumetric Modulated Arc Therapy (VMAT). The device has been used to extract a 2D map of a VMAT lung plan, showing promising performances.

Large-area segmented polycrystalline cvd diamond for dose mapping in advanced radiotherapy techniques / Bruzzi M.; Baldi A.; Bartoli A.; Cupparo I.; Pallotta S.; Pasquini A.; Scaringella M.; Talamonti C.. - ELETTRONICO. - 2017-:(2017), pp. 1-4. (Intervento presentato al convegno 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016 tenutosi a fra nel 2016) [10.1109/NSSMIC.2016.8069394].

Large-area segmented polycrystalline cvd diamond for dose mapping in advanced radiotherapy techniques

Bruzzi M.;Bartoli A.;Cupparo I.;Pallotta S.;Scaringella M.;Talamonti C.
2017

Abstract

Diamond has a potential for dosimetry in advanced radiotherapy techniques, being a solid-state nearly tissue equivalent material, with the possibility to be grown in large diameter wafers by Chemical Vapour Deposition (CVD). A largearea bidimensional dosimeter made of up to two detector-grade adjacent 2.5×2.5cm2 polycrystalline Chemical Vapour Deposited (pCVD) diamond samples, each equipped with a 12×12 matrix of contacts and connected to a custom-made electronic read-out system, has been manufactured in view to achieve fast dynamics as well as spatial and time resolutions required in advanced radiotherapic techniques, such as Volumetric Modulated Arc Therapy (VMAT). The device has been used to extract a 2D map of a VMAT lung plan, showing promising performances.
2017
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop, NSS/MIC/RTSD 2016
fra
2016
Bruzzi M.; Baldi A.; Bartoli A.; Cupparo I.; Pallotta S.; Pasquini A.; Scaringella M.; Talamonti C.
File in questo prodotto:
File Dimensione Formato  
Large-area_segmented_polycrystalline_CVD_diamond_for_dose_mapping_in_advanced_radiotherapy_techniques.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 410.33 kB
Formato Adobe PDF
410.33 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1256123
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact