Introduction: Piggyback IntraOcular Lenses (IOLs), or supplementary secondary implant lenses, have been developed to provide a sufficient dioptric power in eyes with high refractive defects, which are not fully correctable after cataract surgery with single IOL in the range of powers available. These lenses can also be used for the correction of refractive errors that occurred for a wrong choice of the IOL power after cataract surgery. Case description: We report the case of a complete refractive success obtained in a patient with an abnormal cornea, with a central stable ectasia, with thinning, high myopic astigmatism and cataract, obtained with the implant of a primary posterior chamber IOL at the time of cataract surgery and a subsequent implant of a secondary piggyback, sulcus-based customized toric IOL (Camellens FIL 622-2 Toric Monofocal IOL, Soleko, Rome, Italy). Conclusions: This brief report demonstrates the utility of combining primary and piggyback IOLs implant for the correction of a complex spherical-cylindrical refractive defect in a case of abnormal cornea and cataract.

Combining primary and sulcus piggyback IOLs for the correction of a spherical-cylindrical defect in an eye with abnormal cornea / Franco F.G.S.; Nicolosi C.; Vicini G.; Grasso Cannizzo P.; Virgili G.; Giansanti F.. - In: EUROPEAN JOURNAL OF OPHTHALMOLOGY. - ISSN 1120-6721. - ELETTRONICO. - (2021), pp. 0-0. [10.1177/11206721211037824]

Combining primary and sulcus piggyback IOLs for the correction of a spherical-cylindrical defect in an eye with abnormal cornea

Franco F. G. S.;Nicolosi C.;Vicini G.;Grasso Cannizzo P.;Virgili G.;Giansanti F.
2021

Abstract

Introduction: Piggyback IntraOcular Lenses (IOLs), or supplementary secondary implant lenses, have been developed to provide a sufficient dioptric power in eyes with high refractive defects, which are not fully correctable after cataract surgery with single IOL in the range of powers available. These lenses can also be used for the correction of refractive errors that occurred for a wrong choice of the IOL power after cataract surgery. Case description: We report the case of a complete refractive success obtained in a patient with an abnormal cornea, with a central stable ectasia, with thinning, high myopic astigmatism and cataract, obtained with the implant of a primary posterior chamber IOL at the time of cataract surgery and a subsequent implant of a secondary piggyback, sulcus-based customized toric IOL (Camellens FIL 622-2 Toric Monofocal IOL, Soleko, Rome, Italy). Conclusions: This brief report demonstrates the utility of combining primary and piggyback IOLs implant for the correction of a complex spherical-cylindrical refractive defect in a case of abnormal cornea and cataract.
2021
0
0
Franco F.G.S.; Nicolosi C.; Vicini G.; Grasso Cannizzo P.; Virgili G.; Giansanti F.
File in questo prodotto:
File Dimensione Formato  
11206721211037824.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 14.08 MB
Formato Adobe PDF
14.08 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1257368
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact