Fibrinolysis can be abnormally activated in several critical care settings but it's often misdiagnosed by standard laboratory tests. Although rotational thromboelastometry can assess the whole coagulative process, its ability to detect fibrinolysis has been questioned. Aim of this study was to investigate the ability of thromboelastometry in detecting induced fibrinolysis in an in-vitro model. Whole blood samples were taken from 18 healthy volunteers. Each sample was split and added with increasing urokinase concentrations till to reach 0, 50, 75 and 100 IU/ml. Thromboelastometry tests, extem and aptem, were performed on the obtained samples. If significant lysis at 50 IU/ml was recorded, also 10, 25 and 35 IU/ml drug concentrations were tested. No lytic effects were detected in 10 IU/ml samples. Lysis variables were the most sensitive in detecting fibrinolysis even at 25 IU/ml (P < 0.05). Clot firmness parameters were also affected by urokinase, but only at the two highest drug concentrations (P < 0.05). Extem/aptem ratio enhanced the sensitivity of these parameters only if lysis was more marked. Analysing groups of different lysis severity, the time to achieve maximum clot firmness could anticipate an ongoing fulminant or intermediate lysis with 100% sensitivity and 100% specificity (P < 0.05) when lower than 1341.5 s. Rotational thromboelastometry could detect fibrinolysis when it was induced in vitro by 25 IU/ml urokinase or more. Apart from the parameters specific for lysis, time to achieve maximum clot firmness appeared as the earliest indicator of fibrinolysis with high sensitivity and specificity especially if a more intense lysis was going on.

Rotational thromboelastometry for diagnosis of fibrinolysis induced by urokinase in an in-vitro model / Bevilacqua S.; Paniccia R.; Galeotti I.; Viappiani A.; Dimizio F.; Bartolozzi C.; Marcucci R.; Stefano P.. - In: BLOOD COAGULATION & FIBRINOLYSIS. - ISSN 0957-5235. - ELETTRONICO. - 33:(2022), pp. 42-50. [10.1097/MBC.0000000000001102]

Rotational thromboelastometry for diagnosis of fibrinolysis induced by urokinase in an in-vitro model

Bevilacqua S.;Paniccia R.;Marcucci R.;Stefano P.
2022

Abstract

Fibrinolysis can be abnormally activated in several critical care settings but it's often misdiagnosed by standard laboratory tests. Although rotational thromboelastometry can assess the whole coagulative process, its ability to detect fibrinolysis has been questioned. Aim of this study was to investigate the ability of thromboelastometry in detecting induced fibrinolysis in an in-vitro model. Whole blood samples were taken from 18 healthy volunteers. Each sample was split and added with increasing urokinase concentrations till to reach 0, 50, 75 and 100 IU/ml. Thromboelastometry tests, extem and aptem, were performed on the obtained samples. If significant lysis at 50 IU/ml was recorded, also 10, 25 and 35 IU/ml drug concentrations were tested. No lytic effects were detected in 10 IU/ml samples. Lysis variables were the most sensitive in detecting fibrinolysis even at 25 IU/ml (P < 0.05). Clot firmness parameters were also affected by urokinase, but only at the two highest drug concentrations (P < 0.05). Extem/aptem ratio enhanced the sensitivity of these parameters only if lysis was more marked. Analysing groups of different lysis severity, the time to achieve maximum clot firmness could anticipate an ongoing fulminant or intermediate lysis with 100% sensitivity and 100% specificity (P < 0.05) when lower than 1341.5 s. Rotational thromboelastometry could detect fibrinolysis when it was induced in vitro by 25 IU/ml urokinase or more. Apart from the parameters specific for lysis, time to achieve maximum clot firmness appeared as the earliest indicator of fibrinolysis with high sensitivity and specificity especially if a more intense lysis was going on.
2022
33
42
50
Goal 3: Good health and well-being for people
Bevilacqua S.; Paniccia R.; Galeotti I.; Viappiani A.; Dimizio F.; Bartolozzi C.; Marcucci R.; Stefano P.
File in questo prodotto:
File Dimensione Formato  
Rotational_thromboelastometry_for_diagnosis_of.6.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 347.57 kB
Formato Adobe PDF
347.57 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1258835
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact