Atom interferometry on optical clock transitions is being pursued for numerous long-baseline exper-iments both terrestrially and for future space missions. Crucial to meeting the required sensitivities of these experiments is the implementation of large momentum transfer (> 103hk). Here, we show that to sequentially apply such a large momentum via pi pulses places stringent requirements on the frequency noise of the interferometry laser and we find that the linewidth is required to be considerably lower than the previous estimate of approximately 10 Hz. This is due to imperfect pulse fidelity in the presence of noise and is apparent even for an atom at rest interacting with resonant light, making this a fundamen-tal constraint on operational fidelity for a given laser and pulse sequence. Within this framework, we further present and analyze two high-power frequency-stabilized laser sources designed to perform inter-ferometry on the 1S0-3P0 clock transitions of cadmium and strontium, operating at 332 nm and 698 nm, respectively.

Practical Limits for Large-Momentum-Transfer Clock Atom Interferometers / Chiarotti, M; Tinsley, JN; Bandarupally, S; Manzoor, S; Sacco, M; Salvi, L; Poli, N. - In: PRX QUANTUM. - ISSN 2691-3399. - STAMPA. - 3:(2022), pp. 030348-1-030348-10. [10.1103/PRXQuantum.3.030348]

Practical Limits for Large-Momentum-Transfer Clock Atom Interferometers

Chiarotti, M
Membro del Collaboration Group
;
Tinsley, JN
Membro del Collaboration Group
;
Bandarupally, S
Membro del Collaboration Group
;
Manzoor, S
Membro del Collaboration Group
;
Sacco, M
Membro del Collaboration Group
;
Salvi, L
Membro del Collaboration Group
;
Poli, N
Supervision
2022

Abstract

Atom interferometry on optical clock transitions is being pursued for numerous long-baseline exper-iments both terrestrially and for future space missions. Crucial to meeting the required sensitivities of these experiments is the implementation of large momentum transfer (> 103hk). Here, we show that to sequentially apply such a large momentum via pi pulses places stringent requirements on the frequency noise of the interferometry laser and we find that the linewidth is required to be considerably lower than the previous estimate of approximately 10 Hz. This is due to imperfect pulse fidelity in the presence of noise and is apparent even for an atom at rest interacting with resonant light, making this a fundamen-tal constraint on operational fidelity for a given laser and pulse sequence. Within this framework, we further present and analyze two high-power frequency-stabilized laser sources designed to perform inter-ferometry on the 1S0-3P0 clock transitions of cadmium and strontium, operating at 332 nm and 698 nm, respectively.
2022
3
030348-1
030348-10
Chiarotti, M; Tinsley, JN; Bandarupally, S; Manzoor, S; Sacco, M; Salvi, L; Poli, N
File in questo prodotto:
File Dimensione Formato  
PRXQuantum.3.030348.pdf

accesso aperto

Descrizione: versione finale
Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 3.99 MB
Formato Adobe PDF
3.99 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1284419
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact