Fragility curves allow expressing the seismic vulnerability of a given building typology in terms of different damage levels. This work aimed at drawing analytical fragility curves for an existing masonry building type widespread in the Casentino area, within the Arezzo district, dating back to the 1960s-1970s. Generally, these buildings consist of three- or four-storey and they are provided with floors well connected to the vertical walls. The studied building stock was obtained partly from known geometries of actual buildings and partly from a morphological study of existing buildings. The geometric and structural parameters variance was evaluated based on actual features of the buildings within the investigated area. A series of nonlinear FME (Frame by Macro Element) simulations were carried out to calibrate the fragility curves and highlight the most influencing parameters: the material type, the percentage of openings on the building ground floor and the number of floors. Finally, a database of fragility curves was created concerning these most significant parameters on the seismic response of the investigated building typology.

Analytical fragility curves proposal for Tuscan masonry building typologies / Giacomo Lazzerini; Giovanni Menichini; Emanuele Del Monte; Maurizio Orlando; Andrea Vignoli. - In: PROCEDIA STRUCTURAL INTEGRITY. - ISSN 2452-3216. - ELETTRONICO. - 44:(2023), pp. 163-170. (Intervento presentato al convegno Convegno ANIDIS XIX & ASSISi XVII - 2022 tenutosi a Torino nel 11-15 settembre 2022) [10.1016/j.prostr.2023.01.022].

Analytical fragility curves proposal for Tuscan masonry building typologies

Giovanni Menichini;Emanuele Del Monte;Maurizio Orlando;Andrea Vignoli
2023

Abstract

Fragility curves allow expressing the seismic vulnerability of a given building typology in terms of different damage levels. This work aimed at drawing analytical fragility curves for an existing masonry building type widespread in the Casentino area, within the Arezzo district, dating back to the 1960s-1970s. Generally, these buildings consist of three- or four-storey and they are provided with floors well connected to the vertical walls. The studied building stock was obtained partly from known geometries of actual buildings and partly from a morphological study of existing buildings. The geometric and structural parameters variance was evaluated based on actual features of the buildings within the investigated area. A series of nonlinear FME (Frame by Macro Element) simulations were carried out to calibrate the fragility curves and highlight the most influencing parameters: the material type, the percentage of openings on the building ground floor and the number of floors. Finally, a database of fragility curves was created concerning these most significant parameters on the seismic response of the investigated building typology.
2023
Atti del Convegno ANIDIS XIX & ASSISi XVII - 2022
Convegno ANIDIS XIX & ASSISi XVII - 2022
Torino
11-15 settembre 2022
Goal 9: Industry, Innovation, and Infrastructure
Giacomo Lazzerini; Giovanni Menichini; Emanuele Del Monte; Maurizio Orlando; Andrea Vignoli
File in questo prodotto:
File Dimensione Formato  
Procedia SI_XIX ANIDIS_LMDOV.docx

Accesso chiuso

Descrizione: Articolo principale
Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 7.25 MB
Formato Microsoft Word XML
7.25 MB Microsoft Word XML   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1285394
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact