The tetranuclear Cu2+/Ca2+/Ca2(+)/Cu2+ complex based on Malten ligand has been investigated as a platform for anion binding. Simple organic carboxylates and non-steroidal anti-inflammatory drugs (NSAIDs) have been tested, revealing the ability of the platform to bind them. The receiving platform hosts at least two guests in solution although a third anion can be bound, as suggested by X-ray diffraction analysis. The addition of the anions is accompanied by a color change of the solution, making the system a colorimetric sensor for carboxylates (LOD values comprised between 3.6 and 20.7 ppm). A fluorescent system consisting of the 2-(3-oxido-6-oxoxanthen-9-yl)benzoate (fluorescein anion) linked to the tetranuclear platform has been also prepared and used in a chemosensing ensemble approach to signal the presence of the selected anions (Log K between 2.6 and 5.6 for the addition of two guests). The latter also works in a paper strip test, offering the chemosensor a possible practical application.

A Tetranuclear Copper(II)/Calcium(II) Complex as Dual Chemosensor for Colorimetric and Fluorescent Detection of Non-Steroidal Anti-Inflammatory Drugs / Macedi, Eleonora; Giorgi, Luca; Formica, Mauro; Rossi, Patrizia; Paderni, Daniele; Paoli, Paola; Fusi, Vieri. - In: CHEMPLUSCHEM. - ISSN 2192-6506. - ELETTRONICO. - (2023), pp. e202200364.0-e202200364.0. [10.1002/cplu.202200364]

A Tetranuclear Copper(II)/Calcium(II) Complex as Dual Chemosensor for Colorimetric and Fluorescent Detection of Non-Steroidal Anti-Inflammatory Drugs

Rossi, Patrizia;Paoli, Paola;
2023

Abstract

The tetranuclear Cu2+/Ca2+/Ca2(+)/Cu2+ complex based on Malten ligand has been investigated as a platform for anion binding. Simple organic carboxylates and non-steroidal anti-inflammatory drugs (NSAIDs) have been tested, revealing the ability of the platform to bind them. The receiving platform hosts at least two guests in solution although a third anion can be bound, as suggested by X-ray diffraction analysis. The addition of the anions is accompanied by a color change of the solution, making the system a colorimetric sensor for carboxylates (LOD values comprised between 3.6 and 20.7 ppm). A fluorescent system consisting of the 2-(3-oxido-6-oxoxanthen-9-yl)benzoate (fluorescein anion) linked to the tetranuclear platform has been also prepared and used in a chemosensing ensemble approach to signal the presence of the selected anions (Log K between 2.6 and 5.6 for the addition of two guests). The latter also works in a paper strip test, offering the chemosensor a possible practical application.
2023
0
0
Macedi, Eleonora; Giorgi, Luca; Formica, Mauro; Rossi, Patrizia; Paderni, Daniele; Paoli, Paola; Fusi, Vieri
File in questo prodotto:
File Dimensione Formato  
ChemPlusChem - 2023 - Macedi - A Tetranuclear Copper II Calcium II Complex as Dual Chemosensor for Colorimetric and.pdf

accesso aperto

Descrizione: articolo
Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 1.75 MB
Formato Adobe PDF
1.75 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1306170
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact