: Purpose: To compare the refractive results between sutureless scleral fixation intraocular lens (IOLs) (Carlevale, Soleko) and suture-free scleral fixation three-piece IOLs (Sensar AR40, Johnson & Johnson) for secondary implantation in patients with IOL dislocation or aphakia. Methods: This is a monocentric retrospective study on 28 patients (28 eyes) with sutureless scleral fixation Carlevale IOL and 25 patients (25 eyes) with suture-free scleral fixation three-piece IOL. Best-corrected visual acuity (BCVA) evaluation, refractive measures and IOL tilt evaluation with anterior segment optical coherence tomography were conducted at one, three, six and twelve months after surgery. Point Spread Function (PSF) was measured using a total ocular aberrometer. Results: BCVA in both groups improved since the postoperative visit at 1 month and reached a stable value at 3 months At month 12, mean BCVA was 0.23 logMAR in group one and 0.32 logMAR in group two. Mean IOL tilt angle at 12 months was 2.76° ± 1.87 in group one and 2.51° ± 1.80 in group two. PSF at 12 months was 0.18 ± 0.09 in group one and 0.15 ± 0.05 in group two. There were no statistically significant differences (p > 0.05) for all comparisons. The post-operative complications were similar within the two groups. Conclusions: Our results show that secondary IOL implantation has similar visual and surgical outcomes when a sutureless Carlevale lens scleral fixation and a suture-free scleral fixation three-piece IOL are used.

Comparison of Visual and Aberrometric Outcomes in Suture-Free Scleral Fixation: Three-Piece Lenses versus Carlevale Lenses / Franco, Fabrizio; Serino, Federica; Vicini, Giulio; Nicolosi, Cristina; Giansanti, Fabrizio. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - ELETTRONICO. - 12:(2022), pp. 188-188. [10.3390/jcm12010188]

Comparison of Visual and Aberrometric Outcomes in Suture-Free Scleral Fixation: Three-Piece Lenses versus Carlevale Lenses

Franco, Fabrizio;Serino, Federica
;
Vicini, Giulio;Nicolosi, Cristina;Giansanti, Fabrizio
2022

Abstract

: Purpose: To compare the refractive results between sutureless scleral fixation intraocular lens (IOLs) (Carlevale, Soleko) and suture-free scleral fixation three-piece IOLs (Sensar AR40, Johnson & Johnson) for secondary implantation in patients with IOL dislocation or aphakia. Methods: This is a monocentric retrospective study on 28 patients (28 eyes) with sutureless scleral fixation Carlevale IOL and 25 patients (25 eyes) with suture-free scleral fixation three-piece IOL. Best-corrected visual acuity (BCVA) evaluation, refractive measures and IOL tilt evaluation with anterior segment optical coherence tomography were conducted at one, three, six and twelve months after surgery. Point Spread Function (PSF) was measured using a total ocular aberrometer. Results: BCVA in both groups improved since the postoperative visit at 1 month and reached a stable value at 3 months At month 12, mean BCVA was 0.23 logMAR in group one and 0.32 logMAR in group two. Mean IOL tilt angle at 12 months was 2.76° ± 1.87 in group one and 2.51° ± 1.80 in group two. PSF at 12 months was 0.18 ± 0.09 in group one and 0.15 ± 0.05 in group two. There were no statistically significant differences (p > 0.05) for all comparisons. The post-operative complications were similar within the two groups. Conclusions: Our results show that secondary IOL implantation has similar visual and surgical outcomes when a sutureless Carlevale lens scleral fixation and a suture-free scleral fixation three-piece IOL are used.
2022
12
188
188
Franco, Fabrizio; Serino, Federica; Vicini, Giulio; Nicolosi, Cristina; Giansanti, Fabrizio
File in questo prodotto:
File Dimensione Formato  
jcm-12-00188.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 801.59 kB
Formato Adobe PDF
801.59 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1311781
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact