Aims The diagnosis of acute aortic syndromes (AASs) is challenging and requires integrated strategies. Transthoracic focused cardiac ultrasound (FoCUS) is endorsed by guidelines as a first-line/triage tool allowing rapid bedside assessment of the aorta. However, the performance of FoCUS in the European Society of Cardiology-recommended workup of AASs awaits validation.Methods and results This was a prespecified subanalysis of the ADvISED multicentre prospective study. Patients with suspected AAS underwent FoCUS for detection of direct/indirect signs of AAS. Clinical probability assessment was performed with the aortic dissection detection risk score (ADD-RS). Case adjudication was based on advanced imaging, surgery, autopsy, or 14-day follow-up. An AAS was diagnosed in 146 (17.4%) of 839 patients. Presence of direct FoCUS signs had a sensitivity and specificity of 45.2% [95% confidence interval (CI) 37-53.6%] and 97.4% (95% CI 95.9-98.4%), while presence of any FoCUS sign had a sensitivity and specificity of 89% (95% CI 82.8-93.6%) and 74.5% (95% CI 71-77.7%) for AAS. The additive value of FoCUS was most evident within low clinical probability (ADD-RS <= 1). Herein, direct FoCUS signs were identified in 40 (4.8%) patients (P<0.001), including 29 with AAS. ADD-RS <= 1 plus negative FoCUS for AAS rule-out had a sensitivity of 93.8% (95% CI 88.6-97.1%) and a failure rate of 1.9% (95% CI 0.9-3.6%). Addition of negative D-dimer led to a failure rate of 0% (95% CI 0-1.2%).Conclusion FoCUS has additive value in the workup of AASs. Direct FoCUS signs can rapidly identify patients requiring advanced imaging despite low clinical probability. In integrated bundles, negative FoCUS is useful for rule-out of AASs.

Integration of transthoracic focused cardiac ultrasound in the diagnostic algorithm for suspected acute aortic syndromes / Nazerian, Peiman; Mueller, Christian; Vanni, Simone; Soeiro, Alexandre de Matos; Leidel, Bernd A; Cerini, Gabriele; Lupia, Enrico; Palazzo, Andrea; Grifoni, Stefano; Morello, Fulvio. - In: EUROPEAN HEART JOURNAL. - ISSN 1522-9645. - ELETTRONICO. - 40:(2019), pp. 1952-1960. [10.1093/eurheartj/ehz207]

Integration of transthoracic focused cardiac ultrasound in the diagnostic algorithm for suspected acute aortic syndromes

Vanni, Simone;
2019

Abstract

Aims The diagnosis of acute aortic syndromes (AASs) is challenging and requires integrated strategies. Transthoracic focused cardiac ultrasound (FoCUS) is endorsed by guidelines as a first-line/triage tool allowing rapid bedside assessment of the aorta. However, the performance of FoCUS in the European Society of Cardiology-recommended workup of AASs awaits validation.Methods and results This was a prespecified subanalysis of the ADvISED multicentre prospective study. Patients with suspected AAS underwent FoCUS for detection of direct/indirect signs of AAS. Clinical probability assessment was performed with the aortic dissection detection risk score (ADD-RS). Case adjudication was based on advanced imaging, surgery, autopsy, or 14-day follow-up. An AAS was diagnosed in 146 (17.4%) of 839 patients. Presence of direct FoCUS signs had a sensitivity and specificity of 45.2% [95% confidence interval (CI) 37-53.6%] and 97.4% (95% CI 95.9-98.4%), while presence of any FoCUS sign had a sensitivity and specificity of 89% (95% CI 82.8-93.6%) and 74.5% (95% CI 71-77.7%) for AAS. The additive value of FoCUS was most evident within low clinical probability (ADD-RS <= 1). Herein, direct FoCUS signs were identified in 40 (4.8%) patients (P<0.001), including 29 with AAS. ADD-RS <= 1 plus negative FoCUS for AAS rule-out had a sensitivity of 93.8% (95% CI 88.6-97.1%) and a failure rate of 1.9% (95% CI 0.9-3.6%). Addition of negative D-dimer led to a failure rate of 0% (95% CI 0-1.2%).Conclusion FoCUS has additive value in the workup of AASs. Direct FoCUS signs can rapidly identify patients requiring advanced imaging despite low clinical probability. In integrated bundles, negative FoCUS is useful for rule-out of AASs.
2019
40
1952
1960
Nazerian, Peiman; Mueller, Christian; Vanni, Simone; Soeiro, Alexandre de Matos; Leidel, Bernd A; Cerini, Gabriele; Lupia, Enrico; Palazzo, Andrea; Gr...espandi
File in questo prodotto:
File Dimensione Formato  
eurheartj_40_24_1952.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 527.25 kB
Formato Adobe PDF
527.25 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1311840
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 32
social impact