: Due to the increasing diffusion of MDR/XDR Gram-negatives it is necessary to offer reliable antibiotic susceptibility testing (AST), which also include new drugs. Here we evaluated the performances of the VITEK®2 AST-N376 and the AST-N397 cards. A collection of 180 clinical Gram-negative bacteria, producing relevant resistance mechanisms, were tested using VITEK 2 and MERLIN, in parallel. Discrepancies between the 2 systems were solved by the reference broth microdilution method. The workflow timing of the VITEK®2 system was also assessed. Overall, the VITEK®2 cards proved to be reliable in determining AST for the molecules evaluated, even if compliance with ISO acceptance criteria for accuracy assessment was not reached for some combinations and showed a short hands-on time for panels preparation. In conclusion, VITEK®2 is a valid system that ensures accurate results for AST of the molecules evaluated in this study and speeds up the workflow in the laboratory of diagnostic microbiology.

Evaluation of VITEK® 2 AST cards (AST-N376 and AST-N397) for susceptibility testing of challenging Gram negatives / Riccobono, E; Aiezza, N; Niccolai, C; Giani, T; Rossolini, G M. - In: DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE. - ISSN 0732-8893. - ELETTRONICO. - 107:(2023), pp. 116032-116032. [10.1016/j.diagmicrobio.2023.116032]

Evaluation of VITEK® 2 AST cards (AST-N376 and AST-N397) for susceptibility testing of challenging Gram negatives

Riccobono, E;Aiezza, N;Niccolai, C;Giani, T;Rossolini, G M
2023

Abstract

: Due to the increasing diffusion of MDR/XDR Gram-negatives it is necessary to offer reliable antibiotic susceptibility testing (AST), which also include new drugs. Here we evaluated the performances of the VITEK®2 AST-N376 and the AST-N397 cards. A collection of 180 clinical Gram-negative bacteria, producing relevant resistance mechanisms, were tested using VITEK 2 and MERLIN, in parallel. Discrepancies between the 2 systems were solved by the reference broth microdilution method. The workflow timing of the VITEK®2 system was also assessed. Overall, the VITEK®2 cards proved to be reliable in determining AST for the molecules evaluated, even if compliance with ISO acceptance criteria for accuracy assessment was not reached for some combinations and showed a short hands-on time for panels preparation. In conclusion, VITEK®2 is a valid system that ensures accurate results for AST of the molecules evaluated in this study and speeds up the workflow in the laboratory of diagnostic microbiology.
2023
107
116032
116032
Riccobono, E; Aiezza, N; Niccolai, C; Giani, T; Rossolini, G M
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1324013
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact