Diamond is used as detector material in high energy physics experiments due to its inherent radiation tolerance. The RD42 collaboration has measured the radiation tolerance of chemical vapour deposition (CVD) diamond against proton, pion, and neutron irradiation. Results of this study are summarized in this article. The radiation tolerance of diamond detectors can be further enhanced by using a 3D electrode geometry. We present preliminary results of a poly-crystalline CVD (pCVD) diamond detector with a 3D electrode geometry after irradiation and compare to planar devices of roughly the same thickness.

Radiation tolerance of diamond detectors / Bani L.; Artuso M.; Bachmair F.; Bartosik M.; Beck H.; Bellini V.; Belyaev V.; Bentele B.; Bergonzo P.; Bes A.; Brom J.-M.; Chiodini G.; Chren D.; Cindro V.; Claus G.; Collot J.; Cumalat J.; Curtoni S.; Dabrowski A.; D'Alessandro R.; Dauvergne D.; De Boer W.; Dorfer C.; Dunser M.; Eigen G.; Eremin V.; Forneris J.; Gallin-Martel L.; Gallin-Martel M.-L.; Gan K.K.; Gastal M.; Ghimouz A.; Goffe M.; Goldstein J.; Golubev A.; Gorisek A.; Grigoriev E.; Grosse-Knetter J.; Grummer A.; Hiti B.; Hits D.; Hoeferkamp M.; Hofmann T.; Hosselet J.; Hugging F.; Hutson C.; Jackman R.; Janssen J.; Jennings-Moors R.; Kagan H.; Kanxheri K.; Kis M.; Kramberger G.; Kuleshov S.; Lacoste A.; Lagomarsino S.; Giudice A.L.; Paz I.L.; Lukosi E.; Maazouzi C.; Mandic I.; Marcatili S.; Marino A.; Mathieu C.; Menichelli M.; Mikuz M.; Morozzi A.; Moscatelli F.; Moss J.; Mountain R.; Oh A.; Olivero P.; Pakpour-Tabrizi A.; Passeri D.; Pernegger H.; Perrino R.; Picollo F.; Pomorski M.; Porter A.; Potenza R.; Quadt A.; Rarbi F.; Re A.; Reichmann M.; Roe S.; Rossetto O.; Becerra D.A.S.; Schmidt C.; Schnetzer S.; Sciortino S.; Scorzoni A.; Seidel S.; Servoli L.; Smith D.S.; Sopko B.; Sopko V.; Spagnolo S.; Spanier S.; Stenson K.; Stone R.; Stugu B.; Sutera C.; Traeger M.; Trischuk W.; Truccato M.; Tuve C.; Velthuis J.; Wagner S.; Wallny R.; Wang J.C.; Welch J.; Wermes N.; Wickramasinghe J.; Yamouni M.; Zalieckas J.; Zavrtanik M.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - ELETTRONICO. - 2374:(2022), pp. 0-0. [10.1088/1742-6596/2374/1/012172]

Radiation tolerance of diamond detectors

D'Alessandro R.;Sciortino S.
Membro del Collaboration Group
;
2022

Abstract

Diamond is used as detector material in high energy physics experiments due to its inherent radiation tolerance. The RD42 collaboration has measured the radiation tolerance of chemical vapour deposition (CVD) diamond against proton, pion, and neutron irradiation. Results of this study are summarized in this article. The radiation tolerance of diamond detectors can be further enhanced by using a 3D electrode geometry. We present preliminary results of a poly-crystalline CVD (pCVD) diamond detector with a 3D electrode geometry after irradiation and compare to planar devices of roughly the same thickness.
2022
2374
0
0
Bani L.; Artuso M.; Bachmair F.; Bartosik M.; Beck H.; Bellini V.; Belyaev V.; Bentele B.; Bergonzo P.; Bes A.; Brom J.-M.; Chiodini G.; Chren D.; Cin...espandi
File in questo prodotto:
File Dimensione Formato  
Bäni_2022_J._Phys.__Conf._Ser._2374_012172.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 608.49 kB
Formato Adobe PDF
608.49 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1331796
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact