Multisensory human–machine interfaces for virtual- or augmented-reality systems are lacking wearable actuated devices that can provide users with tactile feedback on the softness of virtual objects. They are needed for a variety of uses, such as medical simulators, tele-operation systems and tele-presence environments. Such interfaces require actuators that can generate proper tactile feedback, by stimulating the fingertips via quasi-static (non-vibratory) forces, delivered through a deformable surface, so as to control both the contact area and the indentation depth. The actuators should combine a compact and lightweight structure with ease and safety of use, as well as low costs. Among the few actuation technologies that can comply with such requirements, pneumatic driving appears to be one of the most promising. Here, we present an investigation on a new type of pneumatic wearable tactile displays of softness, recently described by our group, which consist of small inflatable chambers arranged at the fingertips. In order to objectively assess the perceptual response that they can elicit, a systematic electroencephalographic study was conducted on ten healthy subjects. Somatosensory evoked potentials (SEPs) were recorded from eight sites above the somatosensory cortex (Fc2, Fc4, C2 and C4, and Fc1, Fc3, C1 and C3), in response to nine conditions of tactile stimulation delivered by the displays: stimulation of either only the thumb, the thumb and index finger simultaneously, or the thumb, index and middle finger simultaneously, each repeated at tactile pressures of 10, 20 and 30 kPa. An analysis of the latency and amplitude of the six components of SEP signals that typically characterise tactile sensing (P50, N100, P200, N300, P300 and N450) showed that this wearable pneumatic device is able to elicit predictable perceptual responses, consistent with the stimulation conditions. This proved that the device is capable of adequate actuation performance, which enables adequate tactile perceptual performance. Moreover, this shows that SEPs may effectively be used with this technology in the future, to assess variable perceptual experiences (especially with combinations of visual and tactile stimuli), in objective terms, complementing subjective information gathered from psychophysical tests.

EEG Investigation on the Tactile Perceptual Performance of a Pneumatic Wearable Display of Softness / Carpi, Federico; Valles, Michele C.; Frediani, Gabriele; Toci, Tanita; Grippo, Antonello. - In: ACTUATORS. - ISSN 2076-0825. - ELETTRONICO. - 12:(2023), pp. 431.0-431.0. [10.3390/act12120431]

EEG Investigation on the Tactile Perceptual Performance of a Pneumatic Wearable Display of Softness

Carpi, Federico
;
Frediani, Gabriele;Grippo, Antonello
2023

Abstract

Multisensory human–machine interfaces for virtual- or augmented-reality systems are lacking wearable actuated devices that can provide users with tactile feedback on the softness of virtual objects. They are needed for a variety of uses, such as medical simulators, tele-operation systems and tele-presence environments. Such interfaces require actuators that can generate proper tactile feedback, by stimulating the fingertips via quasi-static (non-vibratory) forces, delivered through a deformable surface, so as to control both the contact area and the indentation depth. The actuators should combine a compact and lightweight structure with ease and safety of use, as well as low costs. Among the few actuation technologies that can comply with such requirements, pneumatic driving appears to be one of the most promising. Here, we present an investigation on a new type of pneumatic wearable tactile displays of softness, recently described by our group, which consist of small inflatable chambers arranged at the fingertips. In order to objectively assess the perceptual response that they can elicit, a systematic electroencephalographic study was conducted on ten healthy subjects. Somatosensory evoked potentials (SEPs) were recorded from eight sites above the somatosensory cortex (Fc2, Fc4, C2 and C4, and Fc1, Fc3, C1 and C3), in response to nine conditions of tactile stimulation delivered by the displays: stimulation of either only the thumb, the thumb and index finger simultaneously, or the thumb, index and middle finger simultaneously, each repeated at tactile pressures of 10, 20 and 30 kPa. An analysis of the latency and amplitude of the six components of SEP signals that typically characterise tactile sensing (P50, N100, P200, N300, P300 and N450) showed that this wearable pneumatic device is able to elicit predictable perceptual responses, consistent with the stimulation conditions. This proved that the device is capable of adequate actuation performance, which enables adequate tactile perceptual performance. Moreover, this shows that SEPs may effectively be used with this technology in the future, to assess variable perceptual experiences (especially with combinations of visual and tactile stimuli), in objective terms, complementing subjective information gathered from psychophysical tests.
2023
12
0
0
Goal 3: Good health and well-being
Carpi, Federico; Valles, Michele C.; Frediani, Gabriele; Toci, Tanita; Grippo, Antonello
File in questo prodotto:
File Dimensione Formato  
EEG Investigation on the Tactile Perceptual Performance etc..pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 12.42 MB
Formato Adobe PDF
12.42 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1348634
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact