We report the first detection of an optical millisecond pulsar with the fast photon counter Aqueye+ in Asiago. This is an independent confirmation of the detection of millisecond pulsations from PSR J1023+0038 obtained with SiFAP at the Telescopio Nazionale Galileo. We observed the transitional millisecond pulsar PSR J1023+0038 with Aqueye+ mounted at the Copernicus telescope in 2018 January.Highly significant pulsations were detected. The rotational period is in agreement with the value extrapolated from the X-ray ephemeris, while the time of passage at the ascending node is shifted by 11.55 +/- 0.08 s from the value predicted using the orbital period from the X-rays. An independent optical timing solution is derived over a baseline of a few days that has an accuracy of similar to 0.007 in pulse phase (similar to 12 mu s in time). This level of precision is needed to derive an accurate coherent timing solution for the pulsar and to search for possible phase shifts between the optical and X-ray pulses using future simultaneous X-ray and optical observations.

Precise optical timing of PSR J1023+0038, the first millisecond pulsar detected with Aqueye+ in Asiago / Zampieri, Luca; Burtovoi, Aleksandr; Fiori, Michele; Naletto, Giampiero; Spolon, Alessia; Barbieri, Cesare; Papitto, Alessandro; Ambrosino, Filippo. - In: MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY. LETTERS. - ISSN 1745-3925. - ELETTRONICO. - 485:(2019), pp. 109-113. [10.1093/mnrasl/slz043]

Precise optical timing of PSR J1023+0038, the first millisecond pulsar detected with Aqueye+ in Asiago

Burtovoi, Aleksandr;
2019

Abstract

We report the first detection of an optical millisecond pulsar with the fast photon counter Aqueye+ in Asiago. This is an independent confirmation of the detection of millisecond pulsations from PSR J1023+0038 obtained with SiFAP at the Telescopio Nazionale Galileo. We observed the transitional millisecond pulsar PSR J1023+0038 with Aqueye+ mounted at the Copernicus telescope in 2018 January.Highly significant pulsations were detected. The rotational period is in agreement with the value extrapolated from the X-ray ephemeris, while the time of passage at the ascending node is shifted by 11.55 +/- 0.08 s from the value predicted using the orbital period from the X-rays. An independent optical timing solution is derived over a baseline of a few days that has an accuracy of similar to 0.007 in pulse phase (similar to 12 mu s in time). This level of precision is needed to derive an accurate coherent timing solution for the pulsar and to search for possible phase shifts between the optical and X-ray pulses using future simultaneous X-ray and optical observations.
2019
485
109
113
Zampieri, Luca; Burtovoi, Aleksandr; Fiori, Michele; Naletto, Giampiero; Spolon, Alessia; Barbieri, Cesare; Papitto, Alessandro; Ambrosino, Filippo...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1353569
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact