Background and objectives: We aimed to assess the reliability of preoperative navigated transcranial magnetic stimulation (nTMS) maps for motor function as visualized intraoperatively with augmented reality heads-up display and to assess its accuracy via direct point-by-point comparison with the gold-standard direct cortical stimulation (DCS). Methods: From January 2022 to January 2023, candidates for surgical removal of lesions involving the motor pathways underwent preoperative nTMS assessment to obtain cortical maps of motor function. Intraoperatively and before tumor removal, nTMS maps were superimposed on the cortical surface, and DCS was performed on positive points with increasing current intensity until obtaining a positive response at 16 mA. The outcome of each stimulation was recorded to obtain discrimination metrics. Results: Twelve patients were enrolled (5 females [42%] vs 7 males [58%], mean age 62.9 ± 12.8 years), for a total of 304 investigated points. Agreement between nTMS and DCS was moderate (κ = 0.43, P < .005), with 0.66 (0.53-0.78) sensitivity, 0.87 (0.82-0.90) specificity, 0.50 (0.39-0.62) positive predictive values, 0.93 (0.89-0.95) negative predictive value, and 0.83 (0.79-0.87) accuracy. A loss of accuracy was observed with higher DCS current intensities. Conclusion: We performed a point-by-point validation of preoperative nTMS maps for motor function using augmented reality visualization. The high negative predictive value and low positive predictive values highlight nTMS reliability to visualize safe cortical zones but not to identify critical functional areas, confirming previous findings of nTMS maps for the language function and suggesting the need for combined use of nTMS maps and DCS for optimal maximal safe resection.

Heads-Up Micronavigation Reliability of Preoperative Transcranial Magnetic Stimulation Maps for the Motor Function: Comparison With Direct Cortical Stimulation / Muscas G, Bardazzi T, Pedone A, Campagnaro L, Bonaudo C, Fainardi E, Baldanzi F, Troiano S, Carrai R, Grippo A, Della Puppa A. - In: THE OPEN NEUROSURGERY JOURNAL. - ISSN 1876-5297. - ELETTRONICO. - (2024), pp. 173-179. [10.1227/ons.0000000000000926]

Heads-Up Micronavigation Reliability of Preoperative Transcranial Magnetic Stimulation Maps for the Motor Function: Comparison With Direct Cortical Stimulation

Pedone A;Bonaudo C;Fainardi E;Della Puppa A
2024

Abstract

Background and objectives: We aimed to assess the reliability of preoperative navigated transcranial magnetic stimulation (nTMS) maps for motor function as visualized intraoperatively with augmented reality heads-up display and to assess its accuracy via direct point-by-point comparison with the gold-standard direct cortical stimulation (DCS). Methods: From January 2022 to January 2023, candidates for surgical removal of lesions involving the motor pathways underwent preoperative nTMS assessment to obtain cortical maps of motor function. Intraoperatively and before tumor removal, nTMS maps were superimposed on the cortical surface, and DCS was performed on positive points with increasing current intensity until obtaining a positive response at 16 mA. The outcome of each stimulation was recorded to obtain discrimination metrics. Results: Twelve patients were enrolled (5 females [42%] vs 7 males [58%], mean age 62.9 ± 12.8 years), for a total of 304 investigated points. Agreement between nTMS and DCS was moderate (κ = 0.43, P < .005), with 0.66 (0.53-0.78) sensitivity, 0.87 (0.82-0.90) specificity, 0.50 (0.39-0.62) positive predictive values, 0.93 (0.89-0.95) negative predictive value, and 0.83 (0.79-0.87) accuracy. A loss of accuracy was observed with higher DCS current intensities. Conclusion: We performed a point-by-point validation of preoperative nTMS maps for motor function using augmented reality visualization. The high negative predictive value and low positive predictive values highlight nTMS reliability to visualize safe cortical zones but not to identify critical functional areas, confirming previous findings of nTMS maps for the language function and suggesting the need for combined use of nTMS maps and DCS for optimal maximal safe resection.
2024
173
179
Muscas G, Bardazzi T, Pedone A, Campagnaro L, Bonaudo C, Fainardi E, Baldanzi F, Troiano S, Carrai R, Grippo A, Della Puppa A
File in questo prodotto:
File Dimensione Formato  
Oper Neurosurg 2003_on line first.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 479.2 kB
Formato Adobe PDF
479.2 kB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1355155
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact