Abstract Purpose: To test respiratory-triggered ultrashort echo-time (UTE) Spiral VIBE-MRI sequence in systemic sclerosis-interstitial lung disease assessment compared with computed tomography (CT). Material and Methods: Fifty four SSc patients underwent chest CT and UTE (1.5 T). Two radiologists, independently and in consensus, verified ILD presence/absence and performed a semiquantitative analysis (sQA) of ILD, ground-glass opacities (GGO), reticulations and honeycombing (HC) extents on both scans. A CT software quantitative texture analysis (QA) was also performed. For ILD detection, intra-/inter-reader agreements were computed with Cohen K coefficient. UTE sensitivity and specificity were assessed. For extent assessments, intra-/inter-reader agreements and UTE performance against CT were computed by Lin’s concordance coefficient (CCC). Results: Three UTE were discarded for low quality, 51 subjects were included in the study. Of them, 42 QA segmentations were accepted. ILD was diagnosed in 39/51 CT. UTE intra-/inter-reader K in ILD diagnosis were 0.56 and 0.26. UTE showed 92.8% sensitivity and 75.0% specificity. ILD, GGO, and reticulation extents were 14.8%, 7.7%, and 7.1% on CT sQA and 13.0%, 11.2%, and 1.6% on CT QA. HC was <1% and not further considered. UTE intra-/inter-reader CCC were 0.92 and 0.89 for ILD extent and 0.84 and 0.79 for GGO extent. UTE RET extent intra-/inter-reader CCC were 0.22 and 0.18. UTE ILD and GGO extents CCC against CT sQA and QA were ≥0.93 and ≥0.88, respectively. RET extent CCC were 0.35 and 0.22 against sQA and QA, respectively. Conclusion: UTE Spiral VIBE-MRI sequence is reliable in assessing ILD and GGO extents in systemic sclerosis-interstitial lung disease patients.

Ultrashort Echo-Time Magnetic Resonance Imaging Sequence in the Assessment of Systemic Sclerosis-Interstitial Lung Disease / Landini, Nicholas MD*,†; Orlandi, Martina MD, PhD‡; Occhipinti, Mariaelena MD, PhD†; Nardi, Cosimo MD, PhD†; Tofani, Lorenzo MStat‡; Bellando-Randone, Silvia MD, PhD‡; Ciet, Pierluigi MD, PhD§,∥; Wielopolski, Piotr PhD∥; Benkert, Thomas PhD¶; Bruni, Cosimo MD‡; Bertolo, Silvia MD*; Moggi-Pignone, Alberto MD, PhD#; Matucci-Cerinic, Marco MD, PhD‡; Morana, Giovanni MD*; Colagrande, Stefano MD†. - In: JOURNAL OF THORACIC IMAGING. - ISSN 1536-0237. - ELETTRONICO. - 38:(2023), pp. 97-103. [10.1097/RTI.0000000000000637]

Ultrashort Echo-Time Magnetic Resonance Imaging Sequence in the Assessment of Systemic Sclerosis-Interstitial Lung Disease

Landini;
2023

Abstract

Abstract Purpose: To test respiratory-triggered ultrashort echo-time (UTE) Spiral VIBE-MRI sequence in systemic sclerosis-interstitial lung disease assessment compared with computed tomography (CT). Material and Methods: Fifty four SSc patients underwent chest CT and UTE (1.5 T). Two radiologists, independently and in consensus, verified ILD presence/absence and performed a semiquantitative analysis (sQA) of ILD, ground-glass opacities (GGO), reticulations and honeycombing (HC) extents on both scans. A CT software quantitative texture analysis (QA) was also performed. For ILD detection, intra-/inter-reader agreements were computed with Cohen K coefficient. UTE sensitivity and specificity were assessed. For extent assessments, intra-/inter-reader agreements and UTE performance against CT were computed by Lin’s concordance coefficient (CCC). Results: Three UTE were discarded for low quality, 51 subjects were included in the study. Of them, 42 QA segmentations were accepted. ILD was diagnosed in 39/51 CT. UTE intra-/inter-reader K in ILD diagnosis were 0.56 and 0.26. UTE showed 92.8% sensitivity and 75.0% specificity. ILD, GGO, and reticulation extents were 14.8%, 7.7%, and 7.1% on CT sQA and 13.0%, 11.2%, and 1.6% on CT QA. HC was <1% and not further considered. UTE intra-/inter-reader CCC were 0.92 and 0.89 for ILD extent and 0.84 and 0.79 for GGO extent. UTE RET extent intra-/inter-reader CCC were 0.22 and 0.18. UTE ILD and GGO extents CCC against CT sQA and QA were ≥0.93 and ≥0.88, respectively. RET extent CCC were 0.35 and 0.22 against sQA and QA, respectively. Conclusion: UTE Spiral VIBE-MRI sequence is reliable in assessing ILD and GGO extents in systemic sclerosis-interstitial lung disease patients.
2023
38
97
103
Goal 3: Good health and well-being
Landini, Nicholas MD*,†; Orlandi, Martina MD, PhD‡; Occhipinti, Mariaelena MD, PhD†; Nardi, Cosimo MD, PhD†; Tofani, Lorenzo MStat‡; Bellando-Randone, Silvia MD, PhD‡; Ciet, Pierluigi MD, PhD§,∥; Wielopolski, Piotr PhD∥; Benkert, Thomas PhD¶; Bruni, Cosimo MD‡; Bertolo, Silvia MD*; Moggi-Pignone, Alberto MD, PhD#; Matucci-Cerinic, Marco MD, PhD‡; Morana, Giovanni MD*; Colagrande, Stefano MD†
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1356276
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact