Background: MRI is a radiation-free emerging alternative to CT in systemic sclerosis related interstitial lung disease (SSc-ILD) assessment. We aimed to compare a T2 radial TSE and a PD UTE MRI sequence with CT in SSc-ILD extent evaluation and correlations with pulmonary function tests (PFT). Material and methods: 29 SSc-ILD patients underwent CT, MRI and PFT. ILD extent was visually assessed. Lin's concordance correlation coefficients (CCC) and Kruskal Wallis test (p-value < 0.05) were computed for inter-method comparison. Patients were divided in limited and extended disease, defining extended ILD with two methods: (A) ILD>30% or 10%<= 30% with FVC%<70%; (B) ILD>20% or 20% with FVC%<70%. MRI Sensitivity, Specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Accuracy were assessed. Pearson correlation coefficients r (p-value<0.025) were computed between ILD extents and PFT (FVC% and DLCO%). Results: Median ILD extents were 11%, 11%, 10% on CT, radial TSE and UTE, respectively. CCC between CT and MRI was 0.95 for both sequences (Kruskal-Wallis p-value=0.64). Sensitivity, Specificity, PPV, NPV and Accuracy in identifying extended disease were: (A) 87.5 %, 100 %, 100 %, 95.5 and 96.6 % with radial TSE and 87.5 %, 95.2 %, 87.5 %, 95.2 and 93.1 % with UTE; (B) 86.7 %, 86.4 %, 66.7 %, 95.0 % and 86.2 % for both sequences. Pearson r of CT, radial TSE and UTE ILD extents with FVC were -0.66, -0.60 and -0.68 with FVC, -0.59, -0.56 and -0.57 with DLCO, respectively (p<0.002). Conclusions: MRI sequences may have similar accuracy to CT to determine SSc-ILD extent and severity, with analogous correlations with PFT.

Advanced and traditional chest MRI sequence for the clinical assessment of systemic sclerosis related interstitial lung disease, compared to CT: disease extent analysis and correlations with pulmonary function tests / Landini, Nicholas; Orlandi, Martina; Calistri, Linda; Nardi, Cosimo; Ciet, Pierluigi; Bellando-Randone, Silvia; Guiducci, Serena; Benkert, Thomas; Panebianco, Valeria; Morana, Giovanni; Matucci-Cerinic, Marco; Colagrande, Stefano. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - ELETTRONICO. - 170:(2024), pp. 111239.0-111239.0. [10.1016/j.ejrad.2023.111239]

Advanced and traditional chest MRI sequence for the clinical assessment of systemic sclerosis related interstitial lung disease, compared to CT: disease extent analysis and correlations with pulmonary function tests

Landini, Nicholas;Calistri, Linda;Nardi, Cosimo;Bellando-Randone, Silvia;Guiducci, Serena;Matucci-Cerinic, Marco;Colagrande, Stefano
2024

Abstract

Background: MRI is a radiation-free emerging alternative to CT in systemic sclerosis related interstitial lung disease (SSc-ILD) assessment. We aimed to compare a T2 radial TSE and a PD UTE MRI sequence with CT in SSc-ILD extent evaluation and correlations with pulmonary function tests (PFT). Material and methods: 29 SSc-ILD patients underwent CT, MRI and PFT. ILD extent was visually assessed. Lin's concordance correlation coefficients (CCC) and Kruskal Wallis test (p-value < 0.05) were computed for inter-method comparison. Patients were divided in limited and extended disease, defining extended ILD with two methods: (A) ILD>30% or 10%<= 30% with FVC%<70%; (B) ILD>20% or 20% with FVC%<70%. MRI Sensitivity, Specificity, Positive Predictive Value (PPV), Negative Predictive Value (NPV) and Accuracy were assessed. Pearson correlation coefficients r (p-value<0.025) were computed between ILD extents and PFT (FVC% and DLCO%). Results: Median ILD extents were 11%, 11%, 10% on CT, radial TSE and UTE, respectively. CCC between CT and MRI was 0.95 for both sequences (Kruskal-Wallis p-value=0.64). Sensitivity, Specificity, PPV, NPV and Accuracy in identifying extended disease were: (A) 87.5 %, 100 %, 100 %, 95.5 and 96.6 % with radial TSE and 87.5 %, 95.2 %, 87.5 %, 95.2 and 93.1 % with UTE; (B) 86.7 %, 86.4 %, 66.7 %, 95.0 % and 86.2 % for both sequences. Pearson r of CT, radial TSE and UTE ILD extents with FVC were -0.66, -0.60 and -0.68 with FVC, -0.59, -0.56 and -0.57 with DLCO, respectively (p<0.002). Conclusions: MRI sequences may have similar accuracy to CT to determine SSc-ILD extent and severity, with analogous correlations with PFT.
2024
170
0
0
Goal 3: Good health and well-being
Landini, Nicholas; Orlandi, Martina; Calistri, Linda; Nardi, Cosimo; Ciet, Pierluigi; Bellando-Randone, Silvia; Guiducci, Serena; Benkert, Thomas; Pan...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1357544
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact