Noise pollution is one of the most disturbing environmental factors. It directly affects people’s lives, especially vulnerable people such as children, old-age, and hospital patients. Hospitals are complex buildings with manifold spaces and facilities where different users live with different sensitivity to noise. Several studies highlight the discomfort that patients, staff, and visitors experience in hospitals due to inadequate noise levels. All this leads to stress, sleep disorders, interference in communication, aggression, and annoyance. Noise exposure in hospitals is due to several sound sources. Each varies throughout the day, and their detection could be challenging. The present study proposes a clustering technique to analyze long-term sound level meter monitoring in an Italian hospital (Pisa, Tuscany). Equivalent short-term levels obtained with an interval time of 0.1 s are used as the database to exploit the occurrences curves of different chunks of the monitoring. Then, through a validated method, the spectra of different kinds of sound sources are reconstructed via the Gaussian Mixture Model. Results are compared with near-field measurements of single sources.

Noise within hospital wards: a survey method / Domenico De Salvio, Veronica Amodeo, Dario D’Orazio, Massimo Garai, Simone Secchi. - ELETTRONICO. - (2024), pp. 1-10. (Intervento presentato al convegno 53rd International Congress & Exposition on Noise Control Engineering tenutosi a Nantes, France nel 25-29 august 2024).

Noise within hospital wards: a survey method

Veronica Amodeo;Simone Secchi
2024

Abstract

Noise pollution is one of the most disturbing environmental factors. It directly affects people’s lives, especially vulnerable people such as children, old-age, and hospital patients. Hospitals are complex buildings with manifold spaces and facilities where different users live with different sensitivity to noise. Several studies highlight the discomfort that patients, staff, and visitors experience in hospitals due to inadequate noise levels. All this leads to stress, sleep disorders, interference in communication, aggression, and annoyance. Noise exposure in hospitals is due to several sound sources. Each varies throughout the day, and their detection could be challenging. The present study proposes a clustering technique to analyze long-term sound level meter monitoring in an Italian hospital (Pisa, Tuscany). Equivalent short-term levels obtained with an interval time of 0.1 s are used as the database to exploit the occurrences curves of different chunks of the monitoring. Then, through a validated method, the spectra of different kinds of sound sources are reconstructed via the Gaussian Mixture Model. Results are compared with near-field measurements of single sources.
2024
Proceedings of InterNoise, 53rd International Congress & Exposition on Noise Control Engineering
53rd International Congress & Exposition on Noise Control Engineering
Nantes, France
25-29 august 2024
Domenico De Salvio, Veronica Amodeo, Dario D’Orazio, Massimo Garai, Simone Secchi
File in questo prodotto:
File Dimensione Formato  
IN_2024_3524_240905_180127.pdf

Accesso chiuso

Tipologia: Pdf editoriale (Version of record)
Licenza: Tutti i diritti riservati
Dimensione 2.93 MB
Formato Adobe PDF
2.93 MB Adobe PDF   Richiedi una copia

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1381152
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact