Antimicrobial susceptibility testing (AST) from blood culture (BC) may take several days, limiting the eventual impact on antimicrobial stewardship. Hence, rapid AST systems represent a valuable support in shorting the time-to-response. In this work, the Quantamatrix dRASTTM system (dRAST) was evaluated for rapid AST on 100 monomicrobial BCs (50 Gram-negatives and 50 Gram-positives), including several isolates with clinically relevant resistance mechanisms. AST results were provided in 6-hours, on average. Compared to Micronaut (Merlin) system based on broth microdilution, dRAST exhibited an overall categorical agreement of 92.5 %, essential agreement of 89.0 %, and mean bias of 15.9 %. Category overestimation (potentially leading to unnecessary high-dosage treatment or to exclude active agents) and category underestimation (potentially leading to underdosing or using ineffective agents) were observed in 4.3 % and 3.1 % of cases, respectively. Even though several issues were reported, results confirmed the potential contribution of dRAST to shorten the BCs clinical microbiology workflow and management.

Evaluation of Quantamatrix dRASTTM system for rapid antimicrobial susceptibility testing of bacterial isolates from positive blood cultures, in comparison with commercial Micronaut broth microdilution system / Morecchiato, Fabio; Coppi, Marco; Chilleri, Chiara; Antonelli, Alberto; Giani, Tommaso; Rossolini, Gian Maria. - In: DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE. - ISSN 0732-8893. - ELETTRONICO. - 110:(2024), pp. 116436.0-116436.0. [10.1016/j.diagmicrobio.2024.116436]

Evaluation of Quantamatrix dRASTTM system for rapid antimicrobial susceptibility testing of bacterial isolates from positive blood cultures, in comparison with commercial Micronaut broth microdilution system

Morecchiato, Fabio;Coppi, Marco;Chilleri, Chiara;Antonelli, Alberto;Giani, Tommaso;Rossolini, Gian Maria
2024

Abstract

Antimicrobial susceptibility testing (AST) from blood culture (BC) may take several days, limiting the eventual impact on antimicrobial stewardship. Hence, rapid AST systems represent a valuable support in shorting the time-to-response. In this work, the Quantamatrix dRASTTM system (dRAST) was evaluated for rapid AST on 100 monomicrobial BCs (50 Gram-negatives and 50 Gram-positives), including several isolates with clinically relevant resistance mechanisms. AST results were provided in 6-hours, on average. Compared to Micronaut (Merlin) system based on broth microdilution, dRAST exhibited an overall categorical agreement of 92.5 %, essential agreement of 89.0 %, and mean bias of 15.9 %. Category overestimation (potentially leading to unnecessary high-dosage treatment or to exclude active agents) and category underestimation (potentially leading to underdosing or using ineffective agents) were observed in 4.3 % and 3.1 % of cases, respectively. Even though several issues were reported, results confirmed the potential contribution of dRAST to shorten the BCs clinical microbiology workflow and management.
2024
110
0
0
Morecchiato, Fabio; Coppi, Marco; Chilleri, Chiara; Antonelli, Alberto; Giani, Tommaso; Rossolini, Gian Maria
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1389136
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact