AimsLung ultrasound (LUS) is increasingly used in Internal Medicine to complement medical examination, documenting pleural and lung conditions. This study aimed to compare the accuracy of handheld ultrasound device (HHUSD) with high-end ultrasound device (HEUSD) in patients with heart failure or pneumonia, also including the assessment of costs and time-savings.MethodsIn this observational study 72 patients (aged >= 18) admitted to Internal Medicine Unit for heart failure or pneumonia underwent LUS plus evaluation of inferior cava vein (ICV) when indicated, using both HHUSD and HEUSD. Each evaluation, independently performed by 2 different experienced operators, included B-lines number, pleural effusion, lung consolidations, ICV ectasia and its respiratory excursions.ResultsConcordance between HHUSD and HEUSD findings was 79.3% +/- 17.7 (mean +/- SD) for B-lines, 88.6% for pleural effusion, 82.3% for consolidations and 88.7% and 84.9% for ICV ectasia and its respiratory excursions respectively. BMI didn't significantly influence concordance between the two methods. Moreover, examination time (as mean +/- SD) was shorter with HHUSD (8 +/- 1.5 min) compared to HEUSD (10 +/- 2.5 min).ConclusionsHHUSD demonstrated high accuracy in detecting B-lines, pleural effusions, lung consolidations and ICV evaluation when compared to HEUSD. Thus, HHUSD, not only is characterized by accessibility, portability, and easy handling due to its small size, but it also offers advantages in terms of saving costs and time, ultimately contributing to faster patient assessment compared to HEUSD.
Accuracy of lung ultrasound performed with handheld ultrasound device in internal medicine: an observational study / Lo Cricchio, Anna; Storelli, Andrea; Bertoletti, Iacopo; Ciuti, Gabriele; Fabbri, Alessia; Martinelli, Elisa; De Santis, Maria Cristina; Mercatelli, Paolo; El Aoufy, Khadija; Bellando Randone, Silvia; Moggi Pignone, Alberto; Accogli, Esterita; Bandini, Giulia. - In: JOURNAL OF ULTRASOUND. - ISSN 1876-7931. - ELETTRONICO. - (2024), pp. 1-6. [10.1007/s40477-024-00941-5]
Accuracy of lung ultrasound performed with handheld ultrasound device in internal medicine: an observational study
Lo Cricchio, Anna
;Storelli, Andrea;Bertoletti, Iacopo;Ciuti, Gabriele;Fabbri, Alessia;De Santis, Maria Cristina;Mercatelli, Paolo;El Aoufy, Khadija;Bellando Randone, Silvia;Moggi Pignone, Alberto;Bandini, Giulia
2024
Abstract
AimsLung ultrasound (LUS) is increasingly used in Internal Medicine to complement medical examination, documenting pleural and lung conditions. This study aimed to compare the accuracy of handheld ultrasound device (HHUSD) with high-end ultrasound device (HEUSD) in patients with heart failure or pneumonia, also including the assessment of costs and time-savings.MethodsIn this observational study 72 patients (aged >= 18) admitted to Internal Medicine Unit for heart failure or pneumonia underwent LUS plus evaluation of inferior cava vein (ICV) when indicated, using both HHUSD and HEUSD. Each evaluation, independently performed by 2 different experienced operators, included B-lines number, pleural effusion, lung consolidations, ICV ectasia and its respiratory excursions.ResultsConcordance between HHUSD and HEUSD findings was 79.3% +/- 17.7 (mean +/- SD) for B-lines, 88.6% for pleural effusion, 82.3% for consolidations and 88.7% and 84.9% for ICV ectasia and its respiratory excursions respectively. BMI didn't significantly influence concordance between the two methods. Moreover, examination time (as mean +/- SD) was shorter with HHUSD (8 +/- 1.5 min) compared to HEUSD (10 +/- 2.5 min).ConclusionsHHUSD demonstrated high accuracy in detecting B-lines, pleural effusions, lung consolidations and ICV evaluation when compared to HEUSD. Thus, HHUSD, not only is characterized by accessibility, portability, and easy handling due to its small size, but it also offers advantages in terms of saving costs and time, ultimately contributing to faster patient assessment compared to HEUSD.File | Dimensione | Formato | |
---|---|---|---|
s40477-024-00941-5.pdf
accesso aperto
Tipologia:
Pdf editoriale (Version of record)
Licenza:
Open Access
Dimensione
823.02 kB
Formato
Adobe PDF
|
823.02 kB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.