Goal: Organ perfusion is a vast subject with several techniques, the most common being Hypothermic Machine Perfusion (HMP) and Normothermic Machine Perfusion (NMP). In this paper, a new machine developed at the Biolab of the University of Florence has been tested to validate its capability to perform a well-controlled Oxygenated Rewarming (COR) phase and maintain stability during the NMP phase. Methods: The tests (n=5) were conducted on fresh porcine livers and evaluated according to liver perfusion standards. The developed machine is based on a previous version, with an integrated control and sensor system and a complete mechanical and electronic redesign. Results: The results demonstrate the excellent usability of the machine and its ability to effectively maintain the organs in good condition. The new system performed well, and the measures made on the livers were satisfactory for good preservation of the organ. Conclusion: This study showed the effectiveness of the developed machine. Future development of the system will include a more sophisticated control system to ensure the correct parameters for perfusion.
Experimental Evaluation of a New Perfusion Machine using Normothermic Cycles on Explanted Livers / Barcali, Eleonora; Maggi, Lorenzo; Panconesi, Rebecca; Staderini, Fabio; Bocchi, Leonardo; Nardi, Cosimo; Navari, Nadia; Peris, Adriano; Risaliti, Matteo; Carvalho, Mauricio F.; Marra, Fabio; Dutkowski, Philipp; Grazi, Gian Luca; Schlegel, Andrea; Bigi, Filippo; Dimitri, Mattia; Corvi, Andrea. - In: IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY. - ISSN 2644-1276. - STAMPA. - 6:(2025), pp. 82-88. [10.1109/OJEMB.2024.3478791]
Experimental Evaluation of a New Perfusion Machine using Normothermic Cycles on Explanted Livers
Barcali, Eleonora;Maggi, Lorenzo
;Panconesi, Rebecca;Staderini, Fabio;Bocchi, Leonardo;Nardi, Cosimo;Navari, Nadia;Peris, Adriano;Risaliti, Matteo;Marra, Fabio;Grazi, Gian Luca;Schlegel, Andrea;Bigi, Filippo;Dimitri, Mattia;Corvi, Andrea
2025
Abstract
Goal: Organ perfusion is a vast subject with several techniques, the most common being Hypothermic Machine Perfusion (HMP) and Normothermic Machine Perfusion (NMP). In this paper, a new machine developed at the Biolab of the University of Florence has been tested to validate its capability to perform a well-controlled Oxygenated Rewarming (COR) phase and maintain stability during the NMP phase. Methods: The tests (n=5) were conducted on fresh porcine livers and evaluated according to liver perfusion standards. The developed machine is based on a previous version, with an integrated control and sensor system and a complete mechanical and electronic redesign. Results: The results demonstrate the excellent usability of the machine and its ability to effectively maintain the organs in good condition. The new system performed well, and the measures made on the livers were satisfactory for good preservation of the organ. Conclusion: This study showed the effectiveness of the developed machine. Future development of the system will include a more sophisticated control system to ensure the correct parameters for perfusion.File | Dimensione | Formato | |
---|---|---|---|
Experimental_Evaluation_of_a_New_Perfusion_Machine_Using_Normothermic_Cycles_on_Explanted_Livers.pdf
accesso aperto
Tipologia:
Versione finale referata (Postprint, Accepted manuscript)
Licenza:
Creative commons
Dimensione
1.72 MB
Formato
Adobe PDF
|
1.72 MB | Adobe PDF |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.