Introduction: The radiotherapy workflow involves the collaboration of multiple professionals and the execution of several steps to results in an effective treatment. In this study, we described the clinical implementation of an electronic checklist, developed to standardize the process of the chart review prior to the first treatment fraction by the radiation therapists (RTTs). Materials and Methods: A customized electronic checklist was developed based on the recommendations of American Association of Physicists in Medicine (AAPM) Task Groups 275 and 315 and integrated into the Record and Verify System (RVS). The checklist consisted of 16 items requiring binary (yes/no) responses, with mandatory completion and review by RTTs prior to treatment. The utility of the checklist and its impact on workflow were assessed by analysing checklist reports, and by soliciting feedback to RTTs through an anonymized survey. Results: During the first trial phase, from June to November 2023, 285 checklists were completed with a 98% compilation rate and 94.4% review rate. Forty errors were detected, mainly due to missing signed treatment plans and absence of Beam's Eye View documentation. Ninety percent of detected errors were fixed before the treatment start. In 4 cases, the problem could not be fixed before the first fraction, resulting in a suboptimal first treatment. The feedback survey showed that RTTs described the checklist as useful, with minimal impact on workload, and supported its implementation. Discussion: The introduction of a customized electronic checklist improved the detection and correction of errors, thereby enhancing patient safety. The positive response from RTTs and the minimal impact on workflow underscore the value of the checklist as standard practice in radiotherapy departments.

Enhancing patient safety in radiotherapy: Implementation of a customized electronic checklist for radiation therapists / Lastrucci, Andrea; Esposito, Marco; Serventi, Eva; Marrazzo, Livia; Francolini, Giulio; Simontacchi, Gabriele; Wandael, Yannick; Barra, Angelo; Pallotta, Stefania; Ricci, Renzo; Livi, Lorenzo. - In: TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY. - ISSN 2405-6324. - ELETTRONICO. - 31:(2024), pp. 100255.0-100255.0. [10.1016/j.tipsro.2024.100255]

Enhancing patient safety in radiotherapy: Implementation of a customized electronic checklist for radiation therapists

Lastrucci, Andrea;Serventi, Eva;Marrazzo, Livia;Francolini, Giulio;Simontacchi, Gabriele;Wandael, Yannick;Barra, Angelo;Pallotta, Stefania;
2024

Abstract

Introduction: The radiotherapy workflow involves the collaboration of multiple professionals and the execution of several steps to results in an effective treatment. In this study, we described the clinical implementation of an electronic checklist, developed to standardize the process of the chart review prior to the first treatment fraction by the radiation therapists (RTTs). Materials and Methods: A customized electronic checklist was developed based on the recommendations of American Association of Physicists in Medicine (AAPM) Task Groups 275 and 315 and integrated into the Record and Verify System (RVS). The checklist consisted of 16 items requiring binary (yes/no) responses, with mandatory completion and review by RTTs prior to treatment. The utility of the checklist and its impact on workflow were assessed by analysing checklist reports, and by soliciting feedback to RTTs through an anonymized survey. Results: During the first trial phase, from June to November 2023, 285 checklists were completed with a 98% compilation rate and 94.4% review rate. Forty errors were detected, mainly due to missing signed treatment plans and absence of Beam's Eye View documentation. Ninety percent of detected errors were fixed before the treatment start. In 4 cases, the problem could not be fixed before the first fraction, resulting in a suboptimal first treatment. The feedback survey showed that RTTs described the checklist as useful, with minimal impact on workload, and supported its implementation. Discussion: The introduction of a customized electronic checklist improved the detection and correction of errors, thereby enhancing patient safety. The positive response from RTTs and the minimal impact on workflow underscore the value of the checklist as standard practice in radiotherapy departments.
2024
31
0
0
Goal 3: Good health and well-being
Lastrucci, Andrea; Esposito, Marco; Serventi, Eva; Marrazzo, Livia; Francolini, Giulio; Simontacchi, Gabriele; Wandael, Yannick; Barra, Angelo; Pallot...espandi
File in questo prodotto:
File Dimensione Formato  
main.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Creative commons
Dimensione 731.18 kB
Formato Adobe PDF
731.18 kB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1400082
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact