Transcatheter valve-in-valve implantation is an emerging treatment option for high-risk patients with failing aortic bioprostheses. The presence of the prosthesis stents is thought to prevent coronary artery obstruction, a known complication of transcatheter aortic valve implantation in the native aortic valve. The Sorin Mitroflow aortic bioprosthesis (Sorin Group, Saluggia, Italy) has a particular design in that the pericardial leaflets are mounted outside the valve stent. As a consequence, the pericardial leaflets of this prosthesis may be displaced well away from the stents during the deployment of transcatheter valves. This might explain why both the cases of coronary occlusion following valve-in-valve implantation reported to date occurred in patients with a malfunctioning Mitroflow bioprosthesis. We describe a patient with a malfunctioning 25 mm Mitroflow bioprosthesis successfully treated by percutaneous transcatheter valve-in-valve implantation, and discuss the role that balloon aortic valvuloplasty plays in the performance of this delicate procedure. (c) 2012 Wiley Periodicals, Inc.
Balloon valuloplasty prior to transcatheter valve-in-valve implantation in a degenerated mitroflow aortic bioprosthesis / Cerillo A; Berti S; Glauber M. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - 81:(2013), pp. 1075-1078. [10.1002/ccd.24540]
Balloon valuloplasty prior to transcatheter valve-in-valve implantation in a degenerated mitroflow aortic bioprosthesis
Cerillo A;
2013
Abstract
Transcatheter valve-in-valve implantation is an emerging treatment option for high-risk patients with failing aortic bioprostheses. The presence of the prosthesis stents is thought to prevent coronary artery obstruction, a known complication of transcatheter aortic valve implantation in the native aortic valve. The Sorin Mitroflow aortic bioprosthesis (Sorin Group, Saluggia, Italy) has a particular design in that the pericardial leaflets are mounted outside the valve stent. As a consequence, the pericardial leaflets of this prosthesis may be displaced well away from the stents during the deployment of transcatheter valves. This might explain why both the cases of coronary occlusion following valve-in-valve implantation reported to date occurred in patients with a malfunctioning Mitroflow bioprosthesis. We describe a patient with a malfunctioning 25 mm Mitroflow bioprosthesis successfully treated by percutaneous transcatheter valve-in-valve implantation, and discuss the role that balloon aortic valvuloplasty plays in the performance of this delicate procedure. (c) 2012 Wiley Periodicals, Inc.File | Dimensione | Formato | |
---|---|---|---|
37. Cerillo et al. CCI 2013.pdf
Accesso chiuso
Licenza:
Tutti i diritti riservati
Dimensione
223.06 kB
Formato
Adobe PDF
|
223.06 kB | Adobe PDF | Richiedi una copia |
I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.