Integrated media screens on cardiovascular (CV) exercise equipment have the potential to increase both adherence and effort of exercising participants. However, watching and interacting with media screens is challenging on CV equipment due to conflicting ergonomic needs of 'best' placement for viewing and touching activities. Scientific evaluation is lacking on what is now considered a 'must have' feature on modern exercise equipment. The purpose of this study was to develop a protocol for assessing the ergonomics of fixed screens on CV equipment. Fixed screen position preference, based on users' touching and viewing experience, was compared between 3 methods based on 1 -previous literature including EN ISO 11064-4:2004, 2 - by the user during testing using a free-moving screen, and 3 -the sponsoring company's settings. The study investigated screen height, angle and distance running on a treadmill and cycling on a stationary upright cycle. Seven recreationally active adults, (mean ± SD; 28 ± 6yrs) were selected based on a representative range of eye heights (1 st , 29 th , 50 th , 82 nd and 97 th ).Each subject completed 6 bouts of 5-min exercise on each respective cardiovascular device comprising the 3 different treadmill or bike screen positions and 2 different user operating conditions. Participants interacted with games on-screen during or simply watched TV whilst wearing headphones. In the bike study, seat-height was based on Lemond's coefficient (SICI, 2010) and Participants adopted three generic postural positions (normal, city and chrono). The order of conditions was counterbalanced within the subject group. In both the treadmill and bike study, 50 th percentile Participants preferred the user defined screen positions, but there was little objection to the manufacturer's fixed position which was preferred to the anthropometric devised position.

Development of a Structured Protocol to Determine Multimedia Screen Position on CV Equipment / Francesco Bertiato. - In: INTERNATIONAL JOURNAL OF SPORTS SCIENCE AND ENGINEERING. - ISSN 1750-9831. - ELETTRONICO. - (2012), pp. 0-0.

Development of a Structured Protocol to Determine Multimedia Screen Position on CV Equipment

Francesco Bertiato
Membro del Collaboration Group
2012

Abstract

Integrated media screens on cardiovascular (CV) exercise equipment have the potential to increase both adherence and effort of exercising participants. However, watching and interacting with media screens is challenging on CV equipment due to conflicting ergonomic needs of 'best' placement for viewing and touching activities. Scientific evaluation is lacking on what is now considered a 'must have' feature on modern exercise equipment. The purpose of this study was to develop a protocol for assessing the ergonomics of fixed screens on CV equipment. Fixed screen position preference, based on users' touching and viewing experience, was compared between 3 methods based on 1 -previous literature including EN ISO 11064-4:2004, 2 - by the user during testing using a free-moving screen, and 3 -the sponsoring company's settings. The study investigated screen height, angle and distance running on a treadmill and cycling on a stationary upright cycle. Seven recreationally active adults, (mean ± SD; 28 ± 6yrs) were selected based on a representative range of eye heights (1 st , 29 th , 50 th , 82 nd and 97 th ).Each subject completed 6 bouts of 5-min exercise on each respective cardiovascular device comprising the 3 different treadmill or bike screen positions and 2 different user operating conditions. Participants interacted with games on-screen during or simply watched TV whilst wearing headphones. In the bike study, seat-height was based on Lemond's coefficient (SICI, 2010) and Participants adopted three generic postural positions (normal, city and chrono). The order of conditions was counterbalanced within the subject group. In both the treadmill and bike study, 50 th percentile Participants preferred the user defined screen positions, but there was little objection to the manufacturer's fixed position which was preferred to the anthropometric devised position.
2012
0
0
Francesco Bertiato
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1405997
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact