Alternative powerplant layouts to commonly applied flash technology is investigated for the water dominant geothermal location of Amiata Mountain, Italy. The proposed solution avoids flashing the brine stream by a borehole pump capable of maintaining pressurized conditions, thus reducing the amount of non-condensable gases released when reaching the ground level. Therefore, the need of a gas treatment section is completely avoided. The heat recovered from the hot brine at ground level is transferred to different supercritical CO2 cycle configurations, equipped with high efficiency Printed Circuit Heat Exchangers (PCHE). The optimal 45.5 % calculated exergy efficiency was achieved for the recuperative cycle with intercooling and reheat, which however didn't show the optimal electricity costs (8.092 c€/kWh) because of the more complex heat exchangers network. The lowest cost of electricity (7.4 c€/kWh) was found for the recuperative cycle configuration. These costs are in line with the current levels of geothermal binary cycles, but almost doubled compared to the current single flash + ORC solution, due to a 40–50 % reduction of power output with sCO2 cycles. On the other hand, sCO2 binary cycles could guarantee an almost zero environmental impact, which is the main reason for social concerns related to the current flash powerplants.

Energy, exergy and exergo-economic analyses of supercritical CO2 cycles for the exploitation of a geothermal resource in the Italian water dominant Amiata site / Di Michele, N.; Talluri, L.; Ungar, P.; Fiaschi, D.. - In: ENERGY. - ISSN 0360-5442. - ELETTRONICO. - 313:(2024), pp. 133743.0-133743.0. [10.1016/j.energy.2024.133743]

Energy, exergy and exergo-economic analyses of supercritical CO2 cycles for the exploitation of a geothermal resource in the Italian water dominant Amiata site

Talluri, L.;Ungar, P.;Fiaschi, D.
2024

Abstract

Alternative powerplant layouts to commonly applied flash technology is investigated for the water dominant geothermal location of Amiata Mountain, Italy. The proposed solution avoids flashing the brine stream by a borehole pump capable of maintaining pressurized conditions, thus reducing the amount of non-condensable gases released when reaching the ground level. Therefore, the need of a gas treatment section is completely avoided. The heat recovered from the hot brine at ground level is transferred to different supercritical CO2 cycle configurations, equipped with high efficiency Printed Circuit Heat Exchangers (PCHE). The optimal 45.5 % calculated exergy efficiency was achieved for the recuperative cycle with intercooling and reheat, which however didn't show the optimal electricity costs (8.092 c€/kWh) because of the more complex heat exchangers network. The lowest cost of electricity (7.4 c€/kWh) was found for the recuperative cycle configuration. These costs are in line with the current levels of geothermal binary cycles, but almost doubled compared to the current single flash + ORC solution, due to a 40–50 % reduction of power output with sCO2 cycles. On the other hand, sCO2 binary cycles could guarantee an almost zero environmental impact, which is the main reason for social concerns related to the current flash powerplants.
2024
313
0
0
Di Michele, N.; Talluri, L.; Ungar, P.; Fiaschi, D.
File in questo prodotto:
File Dimensione Formato  
DiMichele2024.pdf

accesso aperto

Tipologia: Pdf editoriale (Version of record)
Licenza: Open Access
Dimensione 3.73 MB
Formato Adobe PDF
3.73 MB Adobe PDF

I documenti in FLORE sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificatore per citare o creare un link a questa risorsa: https://hdl.handle.net/2158/1410334
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact